An official website of the United States government.

This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

OIL SOLUTIONS POWDER

TECHNICAL PRODUCT BULLETIN #M-25
USEPA, OEM REGULATIONS IMPLEMENTATION DIVISION
LISTING DATE: NOVEMBER 9, 2006
“OIL SOLUTIONS POWDER”
(aka, AQUA N-CAP™ POLYMER)

I. NAME, BRAND, OR TRADEMARK
OIL SOLUTIONS POWDER
(aka, AQUA N-CAP™ POLYMER)
II. NAME, ADDRESS, AND TELEPHONE NUMBER OF MANUFACTURER/CONTACT
Oil Solutions International
35 Mill Street
Amityville, NY 11701
Phone: (631) 608-8889
Fax: (631) 789-1676
E-mail: 4oilgreen@gmail.com
Website: www.cleaningupoil.com Exit
(Mr. Dennis J. Traina, President)
III. NAME, ADDRESS, AND TELEPHONE NUMBER OF PRIMARY DISTRIBUTORS
Oil Solutions International
35 Mill Street
Amityville, NY 11701
Phone: (631) 608-8889
Fax: (631) 789-1676
E-mail: 4oilgreen@gmail.com
Website: www.cleaningupoil.com Exit
(Mr. Dennis J. Traina, President)
IV. SPECIAL HANDLING AND WORKER PRECAUTIONS FOR STORAGE AND FIELD APPLICATION
1. Flammability:
Non-flammable
2. Ventilation:
Work in a well ventilated area. Avoid excessive inhalation of dust.
3. Skin and eye contact; protective covering; treatment in case of contact:
Skin contact – No recommendation is made specifying the need for personal protective clothing to prevent skin contact. Person(s) should wash daily at the end of each work shift. Exposed areas should be thoroughly washed with water.
Eye contact – Product may cause irritation as any normal dust. Wear appropriate eye protection, compliant with ANSI Standard Z87.1, to prevent eye contact. If eye irritation or redness is experienced, promptly wash eyes with large amounts of water, for at least 15 minutes, occasionally lifting the lower and upper lids. Should eye irritation persist, seek medical attention immediately. Contact lenses should not be worn when working with this product.
Inhalation – Wear appropriate respiratory protection, compliant with OSHA standard 29 CFR 1910.134, to prevent inhalation. If a respiratory disorder is observed, remove person(s) from the work area immediately. Should respiratory disorder persist, seek medical attention immediately.
Ingestion – Rinse mouth with water and seek medical attention immediately.
4.a. Maximum storage temperature: 185ºF
4.b. Minimum storage temperature: NA
4.c. Optimum storage temperature range: 185ºF
4.d. Temperatures of phase separations and chemical changes: None. Polymer may accumulate static charge during transport, handling, and processing. Static charge can be a potential fire hazard in the presence of volatile or flammable materials or in high airborne dust conditions.
V. SHELF LIFE
Not limited.
VI. RECOMMENDED APPLICATION PROCEDURE
1. Application Method:
Apply OIL SOLUTIONS POWDER along the outer edges of spill area to prevent spill migration. Proceed by applying product onto remaining spill area, until a light white excess of product is observed. OIL SOLUTIONS POWDER may be broadcast onto the spill by hand or with a mechanical blower. Lighter hydrocarbons and synthetic oils will clump into a soft cluster like material easily recoverable with a net or other means as appropriate.
2. Concentration/Application Rate:
Apply OIL SOLUTIONS POWDER at a rate of 0.5 to 2 lbs per gallon of spilled hydrocarbon. Depending on the type of hydrocarbon and recovery operations employed, more or less product may be used to achieve recoverable solid mat/residue. Allow approximately 30 – 60 minutes of contact time, product will form an elastic or rubber-like mat material. Mat like material may be removed whole or segmented as appropriate.
3. Conditions for Use:
OIL SOLUTIONS POWDER differs from traditional sorbents in that it initially behaves like a synthetic sorbent, then as a solidifier as the molecular microencapsulating process occurs. Once encapsulated, the spilled oil is captured within the polymer matrix. OIL SOLUTIONS POWDER is designed to cleanup a wide variety of crude oil, refined hydrocarbon products (i.e., fuels, oils, hydraulic fluids), and synthetic fluids spilled on water and surfaces.
VII. TOXICITY AND EFFECTIVENESS
a. Toxicity:
Material Tested Species LC50 (ppm)
OIL SOLUTIONS POWDER Menidia beryllina
Mysidopsis bahia
484,000 96-hr

104,000 48-hr

No. 2 Fuel Oil Menidia beryllina
Mysidopsis bahia
15.80 96-hr
1.45 48-hr
OIL SOLUTIONS POWDER Menidia beryllina
Mysidopsis bahia
22.50 96-hr
2.13 48-hr
Reference Toxicant (DSS) Menidia beryllina
Mysidopsis bahia
3.65 96-hr
9.55 48-hr

b. Effectiveness:
NA

VIII. MICROBIOLOGICAL ANALYSIS
NA
IX. PHYSICAL PROPERTIES
1. Flash Point: 230ºF
2. Pour Point: NA
3. Viscosity: NA
4. Specific Gravity: 0.92
5. pH: NA
6. Surface Active Agents: NA
7.Solvents: NA
8. Additives: None
9.Solubility in Water: Negligible
X. ANALYSIS FOR HEAVY METALS, CYANIDE, AND CHLORINATED HYDROCARBONS
Compound Concentration (ppm)
Arsenic <1.0
Cadmium <0.05
Chromium <0.325
Copper 17.25
Lead <0.08
Mercury 0.02
Nickel <0.225
Zinc <0.45
Cyanide <0.1
Chlorinated Hydrocarbons ND