An official website of the United States government.

This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

X4JH2000

TECHNICAL PRODUCT BULLETIN #SW-70
USEPA, OEM REGULATIONS IMPLEMENTATION DIVISION
LISTING DATE: MARCH 05, 2019
"X4JH2000"

I. NAME, BRAND, OR TRADEMARK
X4JH2000
Type of Product: Surface Washing Agent
II. NAME, ADDRESS, AND TELEPHONE NUMBER OF MANUFACTURER/CONTACT
X4 Environmental Inc.
14702 Jersey Shore Drive
Houston, TX 77047
Phone: (281) 846-6003
E-mail: benlux.tam@x4environmental.com
(TszFung Benlux Tam)
III. NAME, ADDRESS, AND TELEPHONE NUMBER OF PRIMARY DISTRIBUTORS
X4 Environmental Inc.
14702 Jersey Shore Drive
Houston, TX 77047
Phone: (281) 846-6003
E-mail: benlux.tam@x4environmental.com
(TszFung Benlux Tam)
IV. SPECIAL HANDLING AND WORKER PRECAUTIONS FOR STORAGE AND FIELD APPLICATION
1. Flammability: Non-flammable
2. Ventilation: Recommend using a respirator in confined areas.
3. Skin and eye contact; protective covering; treatment in case of contact: Wear rubber gloves and eye protection. In case of eye contact, wash eyes thoroughly for 15 minutes including upper and lower lids; and seek medical attention. In case of skin contact, irritation is possible; wash with soap and water for 15 minutes. If irritation persists, seek medical attention.
4.a. Maximum storage temperature: 95°F
4.b. Minimum storage temperature: 32ºF
4.c. Optimum storage temperature range: 75°F
4.d. Temperatures of phase separations and chemical changes: No phase changes have been observed
V. SHELF LIFE

One year in a sealed container; and six months for an opened container.

VI. RECOMMENDED APPLICATION PROCEDURE
1. Application Method: X4JH2000 is applied by spraying apparatus or mixing on or into media using excavator and 2-inch discharge hose, fire nozzle, or water pump; and water trucks.
2. Concentration/Application Rate: X4JH2000 is a water-based chemical. Use a ratio of 1 to 1.5 U.S. gallons of X4JH2000 to 10 parts water (i.e., tap, salt or fresh water) per cubic yard of contaminated media.
3. Conditions for Use: Ambient temperature should be above 50ºF. Water salinity and age of hydrocarbon pollutants are not a condition of use. Prior to application, use oil spill absorbent, boom and/or pad to prevent X4JH2000 from run off into ditches, creeks, and waterways. Place collected booms, pads, and absorbents in black 55-gallon poly-bags, use duct tape to seal, and then place bags in hazardous waste container for disposal. Collected containment materials should be disposed of according to local, state, and federal regulations.
VII. TOXICITY AND EFFECTIVENESS
a. Toxicity:
Material Tested Species LC50 (ppm)
X4JH2000 Menidia beryllina
Mysidopsis bahia
145.89 96-hr
40.26 48-hr
No. 2 Fuel Oil Menidia beryllina
Mysidopsis bahia
18.82 96-hr
1.49 48-hr
X4JH2000 & No. 2 Fuel Oil (1:10) Menidia beryllina
Mysidopsis bahia
18.59 96-hr
2.07 48-hr
Reference Toxicant (SLS) Menidia beryllina
Mysidopsis bahia
4.64 96-hr
8.42 48-hr

b. Effectiveness
NA
VIII. MICROBIOLOGICAL ANALYSIS
NA
IX. PHYSICAL PROPERTIES
1. Flash Point (ASTM D-56): >220ºF
2. Pour Point (ASTM D-57): +28ºF
3. Viscosity (ASTM D-445): 4.99cSt at 40ºC
4. Specific Gravity (ASTM D-1298): 1.06 at 60ºF
5. pH (ASTM D-1293): 4.69
6. Surface Active Agents: HS Code 340211 anionic organic surface-active agents
7. Solvents: Not applicable
8. Additives: Not applicable
9. Solubility in Water: Not applicable
X. ANALYSIS FOR HEAVY METALS, CYANIDE, AND CHLORINATED HYDROCARBONS
Compound Concentration (ppm)
Arsenic <0.050
Cadmium <0.025
Chromium <0.050
Copper <0.100
Lead <0.050
Mercury <0.010
Nickel <0.050
Zinc 0.461
Cyanide <0.025
Chlorinated Hydrocarbons <1.000

Top of Page