Can positive buoyancy models be used?
Yes, provided there is a basis for use and the owner or operator explains the rationale for use of positive buoyancy models.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Yes, provided there is a basis for use and the owner or operator explains the rationale for use of positive buoyancy models.
What should a facility do if it submitted a risk management plan (RMP) but later discovers that it was never subject to the risk management program requirements? If a facility discovers that it submitted an RMP in error and was never subject to the risk management program regulations, it should…
A process involving a regulated substance had an accidental release with off-site consequences two years ago. The process has been shut down. Do I have to report anyway? No. The release does not have to be reported in your accident history. Your Risk Management Plan only needs to address operating…
What level of off-site property damage triggers reporting? Any level of known offsite property damage triggers inclusion of the accident in the five-year accident history. You are not required to conduct a survey to determine if such damage occurred, but if you know, or could reasonably be expected to know…
Under the risk management program regulations at 40 CFR Part 68, sources with Program 2 and Program 3 covered processes are required to develop prevention programs that include personnel training. Will compliance with the training requirements under OSHA's Process Safety Management standard (PSM) satisfy the training requirements under 40 CFR…
According to the definition of "process" in 40 CFR §68.3, any group of vessels that are interconnected is considered to be a single process. If a stationary source has two interconnected vessels and one contains 6,000 pounds of butane while the other contains 6,000 pounds of propane, is this a…
If a stationary source includes processes that are subject to both the OSHA process safety management (PSM) standard and the Program 3 risk management program requirements, what must the owner or operator of the stationary source do to demonstrate compliance under 40 CFR Part 68? A source owner or operator…
I operate a single covered process on a site owned by a large company. I manufacture a regulated substance that I pipe to the other company for use in its processes. At what point do the piping and substance become part of the other company’s stationary source? The answer will…
Tube trailers carry bulk liquids that are stacked in a rack type arrangement on the back of a truck trailer. This arrangement often is used to carry highly hazardous materials such as anhydrous hydrogen chloride. The tubes are manifolded together, but usually only one tube at a time is connected…
A toxic substance is never aggregated with a different toxic substance to determine whether a threshold quantity is present. If your process consists of co-located vessels with different toxic substances, you must determine whether each substance exceeds its threshold quantity. A flammable substance in one vessel is never aggregated with…
No. Explosives classified by the Department of Transportation as Class 1, Division 1.1 were initially listed as regulated substances with a threshold quantity of 5,000 pounds because of their potential to cause offsite impacts (59 FR 4478; January 31, 1994). In accordance with a Settlement Agreement between EPA and the…
Are there any overall industry exemptions from the Accidental Release Prevention provisions and Risk Management Program regulations? No. However, there are exemptions that are widely applicable and affect many facilities in certain sectors. For example, ammonia used as an agricultural nutrient, when held by farmers, is exempt from part 68…
An existing certifying official already has a Central Data Exchange (CDX) account and has certified Risk Management Plans (RMPs) for a facility in the past after submitting an Electronic Signature Agreement (ESA). When certifying an RMP for a new facility, is the certifying official required to sign another ESA for…
A flammable substance listed in 40 CFR §68.130 is excluded from the risk management program regulations when it is used as a fuel or held for sale as a fuel at a retail facility (§68.126). What is the definition of fuel for the purposes of this exclusion? There is no…
The regulations in 40 CFR §§68.58 and 68.79 require the owner or operator of facilities to conduct and document compliance audits at least every three years, although an owner or operator is not required to conduct a compliance audit prior to submitting a facility’s first RMP. Must an owner or…