This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

Fuels Registration, Reporting, and Compliance Help

For those with graphical data on E200/E300, will EPA allow use of either the equation or graphical for both baseline and compliance?

Graphical approaches to calculating E200 and E300 for all fuels (i.e. both baseline and compliance fuels) can be used when curve-fitting or linear interpolation are not feasible. The conversion equations provided in the regulations can only be used if the only data available to a refiner is T50 and T90 measurements (i.e. no other distillation data is available).(7/1/94)

This question and answer was posted at Consolidated List of Reformulated Gasoline and Anti-Dumping Questions and Answers: July 1, 1994 through November 10, 1997 (PDF)(333 pp, 18.17 MB, EPA420-R-03-009, July 2003, About PDF)