An official website of the United States government.

This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

Fuels Registration, Reporting, and Compliance Help

What options are available to pipelines for dealing with interface material, i.e., mixtures of two different types of product that result when the different products are adjacent during pipeline movement?

Interface Mixtures Involving RFG or RBOB

First, the pipeline must minimize the instances of prohibited mixing, through the sequencing together of product types that may be legally mixed, to the greatest extent possible.

Second, in those instances where illegal interface mixing occurs, the entire interface
must be added to the product that will most ensure no adverse environmental
consequences of the mixing. For example:

a. Interface mixtures of RFG or RBOB and conventional gasoline must be classified as conventional gasoline.

b. Interface mixtures of VOC-controlled RFG and non-VOC-controlled RFG must be classified as non-VOC-controlled RFG. 16

c. Interface mixtures of VOC-controlled RFG for Region 1 and VOC-controlled RFG for Region 2 must be classified as VOC-controlled RFG for Region 2 or as non-VOC-controlled RFG.

d. Interface mixtures of OPRG-designated RFG and non-OPRG-designated RFG must be classified as non-OPRG-designated RFG.

e. Interface mixtures of VOC-controlled, OPRG RFG and non-VOC-controlled, non-OPRG RFG must be classified as non-VOC-controlled, non-OPRG RFG.

f. Interface mixtures of RBOB and RFG must be classified as RBOB.
g. Interface mixtures of any-oxygenate RBOB and ether-only RBOB must be classified as ether-only RBOB.

h. Interface mixtures of generic RBOB (i.e., any-oxygenate or ether-only RBOB) and refiner-specific RBOB (under § 80.69(a)(1)) must be classified as refiner-specific RBOB.

Third, the pipeline must retain documents that reflect the nature of any illegal
interface mixing and that the interface was classified in the proper manner, and must
make these documents available to EPA upon request.

Interface Mixtures Involving Conventional Gasoline and Not Involving RFG

In the case of interface mixtures that do not involve RFG or RBOB, pipelines may follow their historical practices, and will not be treated as a refiner based on such interface mixtures, so long as:

First, the interface to be blended is generated through pipeline operations, i.e., the blending does not involve blendstocks that are present for the purpose of blending.

Second, the conventional gasoline involved meets all standards and requirements that apply to conventional gasoline, including the volatility standards and the substantially similar requirements;

Third, the volumes of interface are recorded and made available for EPA inspections.
For example, in the case of interface mixtures that involve conventional gasoline and blendstocks (natural gasoline, raffinate, naphtha, etc.), if a pipeline historically has used midpoint cuts for this type of interface the pipeline could continue this practice without meeting the "refiner" requirements as a result of any blendstock that would be mixed with conventional gasoline through this process. It would not be appropriate, however, to classify all blendstock-conventional gasoline interface mixtures as conventional gasoline, i.e., to "clean cut" the interface into the conventional gasoline, because this practice would result in a net increase in conventional gasoline volume.

Interface mixtures that include neither RFG nor conventional gasoline are not impacted by the RFG/anti-dumping regulations.

Transmix

EPA understands there are certain types of interface mixtures that cannot be easily added to either of the adjoining products that produced the interface. This primarily is the case of interface mixtures of gasoline and distillate, commonly called "transmix." EPA further understands that the current pipeline industry practice is to transport transmix via pipeline or barge to a facility designed to separate the gasoline and distillate portions. The owner or operator of such a facility is called a "transmix processor," and is a refiner under the RFG and anti-dumping programs.

Transmix Processors

A transmix processor may use the gasoline or gasoline blendstock obtained when transmix is separated to produce RFG or conventional gasoline, so long as the gasoline produced is included in the refinery's RFG and/or anti-dumping compliance calculations for the refinery, and all other refinery requirements are met, including sampling and testing, record keeping, reporting, and attest engagements.

Gasoline produced which is classified as conventional gasoline

In the case of conventional gasoline produced from transmix by a transmix processor, the anti-dumping standards and requirements need not be met provided that the following conditions are met:

First, the transmix used must be a mixture of distillate and gasoline - either RFG or conventional gasoline. If the transmix is a mixture of distillate and blendstock, the blendstock will never have been accounted-for, and the transmix processor must meet the anti-dumping refiner standards and requirements for any gasoline produced using this transmix.

Second, no additional blendstocks may be used. If blendstocks are used, in addition to the transmix, the transmix processor must meet the anti-dumping refinery standards and requirements for this blendstock in the same manner as any other blender-refiner. A transmix processor could, of course, blend gasoline produced through the process with other finished gasoline without invoking the anti-dumping requirements, e.g., premium grade gasoline could be blended to improve octane.

Gasoline produced which is classified as RFG

In the case of RFG produced from transmix by a transmix processor, the following option is available:

First, the transmix processor must meet the requirements that apply to refiners, including the requirement to meet refiner RFG standards under §§ 80.41 and 80.65(c) (with the limited exception described below), sampling and testing under § 80.65(e), independent sampling and testing under § 80.65(f), record keeping under § 80.74, reporting under § 80.75, and attest engagements under §§ 80.125 through 80.128.

Second, the transmix used must be a combination of distillate and RFG, and may not be a mixture of distillate and conventional gasoline. The transmix processor must obtain documents from the transferor of the transmix which certify the gasoline portion of the transmix is RFG, and must retain these documents in the manner specified under § 80.74.

Third, the transmix processor must meet all RFG standards specified in § 80.41(a) or (b), and the standard for T-90 under § 80.41(h)(2)(i) (in the case of transmix processor with the statutory baseline, an annual average T-90 that is equal to or less than 332 °F). The transmix processor need not meet the simple model standards for sulfur and olefins under § 80.41(h)(2)(i) for the RFG produced from transmix. If the transmix processor uses any blendstocks in addition to the transmix, however, the sulfur and olefin standards must be met for these blendstocks.

The distinction between the treatment of a transmix processor who produces RFG versus conventional gasoline is appropriate because the gasoline produced by a transmix processor is not identical to the gasoline that went into the transmix. The changes in gasoline quality through transmix processing are less critical for conventional gasoline than for RFG.

In the case of RFG produced by a transmix processor following the procedures described in this Answer, however, the RFG will meet all refiner standards which are applicable downstream of the refinery level. Even though a transmix processor who produces RFG is not held to the refiner standard for sulfur and olefins (for which there are no downstream standards), EPA believes a transmix processing operation does cause significant changes in the sulfur and olefin levels from the levels of the RFG portion of the transmix received by the processor.

Transmix Blending

EPA understands that in certain limited situations where transmix cannot be transported via pipeline to a transmix processor, current pipeline industry practice is to add the transmix to gasoline in very small quantities - 0.25 percent or less of the gasoline volume - and to test the resulting gasoline to ensure it remains on-spec.17 This practice would be treated as illegal blending under the RFG and anti-dumping programs, unless the blender meets all applicable refiner standards and requirements.

In the case of transmix added to conventional gasoline:

First, the transmix must result from normal pipeline operations.
Second, the transmix must be present in a terminal from which there is no out-bound pipeline or water transportation by which the transmix could be transported to a transmix processor, or the pipeline's historical practice at the terminal (the practice beginning at least before January, 1994) has been to blend all transmix into conventional gasoline without further processing.

Third, the transmix is blended at a rate no greater than the historical rate the pipeline can document was used by the pipeline, and pipeline documents the current rate of transmix blending.

In the case of transmix added to RFG:

First, the transmix must result from pipeline operational necessity.

Second, the transmix must be present in a terminal from which there is no out-bound pipeline or water transportation by which the transmix could be transported to a transmix processor.

Third, conventional gasoline must not be among the slate of products that arrive at the terminal (transmix must be blended with conventional gasoline if possible).

Fourth, the blending rate of transmix to RFG must be no greater than 0.25 percent by volume.

Fifth, the transmix must be blended with RFG in a batch mode, so that a sample may be collected of the entire batch.

Sixth, the transmix-RFG blend must be sampled and tested, and the resulting blend must meet all applicable RFG downstream standards, before any of the blended gasoline leaves the terminal.

Seventh, the pipeline must retain documents that reflect the rate of transmix blending and the results of all testing on the transmix-RFG blend, and must make these documents available to EPA upon request.

As an alternative to blending the transmix in a batch mode with sampling and testing before any of the RFG blended with transmix leaves the terminal, the transmix may be blended with RFG in line provided that the pipeline carries out the following program to ensure the transmix will not cause any adverse environmental consequences.

First, the pipeline must conduct a program of laboratory testing, in which samples of transmix are mixed with RFG to determine the effects of the transmix on the RFG. In this program, the transmix samples must to the greatest extent possible represent the full range of the transmix types that are typically blended by the pipeline, and the RFG must to the greatest extent possible represent the full range of the types of RFG into which transmix will be blended by the pipeline. These different transmixes and gasolines must be blended at the maximum rate of transmix blending the pipeline intends to use, but a maximum of 0.25% transmix by volume.

Second, the RFG must be tested for each RFG parameter (RVP, oxygen, benzene, sulfur, olefins, aromatics, E200, and E300), and the RFG transmix blend must be tested for each of these parameters, using the testing methods specified at § 80.46.

Third, the results of all of the laboratory tests must show that the maximum change in properties of the RFG for any RFG-transmix blend is not more than the ranges specified at § 80.65(e)(2)(i).

Fourth, the pipeline must conduct RFG-transmix blending as described in steps 5 and 6 of the first RFG-transmix procedure, above, for a period of 30 days, and the results of the blending must show that the maximum change in properties of the RFG for any RFG-transmix blend is not more than the ranges specified at § 80.65(e)(2)(i).

Fifth, the pipeline must conduct monthly tests of the RFG-transmix blended, and the results of the blending must show that the maximum change in properties of the RFG for any RFG-transmix blend is not more than the ranges specified at § 80.65(e)(2)(i).

The procedures outlined above for transmix blending would be applicable to terminals as well as pipelines.(11/12/96)
 



16 The mixing of VOC-controlled RFG with non-VOC-controlled RFG is not prohibited during the transition period prior to May 1 each year (prior to June 1 each year for retail outlets), and subsequent to September 15 each year. During the VOC transition period, however, mixtures of VOC-controlled RFG and non-VOC-controlled RFG nevertheless must be classified as non-VOC-controlled unless the resulting mixture meets the applicable VOC downstream standard (as discussed in the Transition section of this document), and during the VOC-control period such mixtures also must be classified as non-VOC-controlled RFG.

17 The transmix is added to gasoline instead of to distillate, because the consequences of any motor vehicle driveability problems resulting from distillate being mixed with gasoline are less serious than the consequences of explosions that could result from gasoline being mixed with distillate.

This question and answer was posted at Consolidated List of Reformulated Gasoline and Anti-Dumping Questions and Answers: July 1, 1994 through November 10, 1997 (PDF)(333 pp, 18.17 MB, EPA420-R-03-009, July 2003, About PDF)