This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

Radon

Why must radon be vented into the air above my home's roof?

Radon gas is approximately 7.5 times heavier than air.  It is however a noble gas with no chemical affinity but is easily influenced by air movements and pressure.  In a house with forced air heating and cooling, radon gas can easily be distributed throughout the entire dwelling. When radon gas is discharged via a radon mitigation system above the roof, the radon concentration falls off dramatically with distance from the point of discharge.  In fact, the radon gas concentration approaches  background levels at 3-4 feet from the discharge point.  EPA disallowed ground level discharge of radon primarily because of the potential for re-entrainment of the gas into the house and because of the possibility of children being exposed to high radon levels.  The concentration of radon gas at the discharge point can be tens of thousands of picocuries per minute.

Read more about radon at https://19january2021snapshot.epa.gov/radon

Read the Consumer's Guide to Radon Reduction.

Read Building Radon Out: A Step-by-Step Guide on How to Build Radon Resistant Homes,