Severstal North America - Permitting Information
1. Facility Information
Severstal North America
2. Location
3001 Miller Rd, Dearborn, MI
3. Distance from US/Canada Border
about 20 Km
4. Facility Type and Size
Steel and iron production facility
5. Sources of Emissions
Blast furnaces, basic oxygen furnace, refining facilities, annealing furnace, slab reheat furnaces
6. Type of Fuel
Natural gas and furnace gas
7. Type and Quantity of Emissions
CO: blast furnace stove limits are 13.7 lb/MMscf blast (furnace gas burned) and 84.0 lb/MMscf (natural gas burned), 61.7 lb/hour
SO2: Furnance stove limits are 14.37 lb/MMscf blast furnace gas burned (58.3 lb/hr) and 16.62 lb/MMscf blast furnace gas burned (67.3 lb/hr) if another blast furnace is not operating; 1465 lb/hr
VOC: 4.31 lb/hr
NOx: 13.5 lb/MMscf (furnace gas burned) and 140 lb/MMscf (natural gas burned)
PM and PM10: from 0.0015 gr/dscf to 0.01 gr/dscf, depending on the equipment
8. Emission Control Technology
Low-NOx burners, baghouses, ESP, good combustion practices fuel sulfur content monitoring
9. Date Permit Application Received
July 13, 2005
10. Stack Height and Diameter
stacks (minimum heights and maximum diameters are in concordance with 40 CFR 52.21 Subparts (c) and (d).
11. Permit Agency Contact
Jim Donaldson
Michigan Department of Environmental Quality,
Air Quality Division,
PO Box 30260
Lansing, MI, 48909 - 7760
Tel. 517 241-7470