This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

Worst-case Release Scenario for Separate, Interconnected Vessels

Pursuant to the risk management program regulations, facilities must perform an offsite consequence analysis for the worst-case release scenario. Do the quantities of two separate vessels that are interconnected with a closed valve need to be aggregated for the worst-case release scenario analysis? 

No. Worst-case release is defined as the release of the largest quantity of a regulated substance from a vessel or process line failure that results in the greatest distance to an endpoint (40 CFR §68.3).  For substances in vessels, the worst-case release scenario should only include the greatest amount of a regulated substance held in a single vessel.

Additional information on offsite consequence analysis requirements can be found in Chapter 4 of the General Guidance on Risk Management Programs for Chemical Accident Prevention (40 CFR Part 68) (EPA550-B-04-001) and in the Risk Management Program Guidance for Offsite Consequence Analysis (EPA 550-B-99-009). Both documents can be found at the following URL:

https://19january2021snapshot.epa.gov/rmp/guidance-facilities-risk-management-programs-rmp