An official website of the United States government.

This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

Louisiana SIP: LAC 33:III Ch 21 Subchap A 2101 to 2122--General

Regulatory Text: 
Louisiana Administrative Code, Title 33 ENVIRONMENTAL QUALITY, Part III Air (LAC 33:III)

Chapter 21. Control of Emission of Organic Compounds

Subchapter A. General

Outline:
Section 2101.  Compliance Schedules. LAc60
Section 2103.  Storage of Volatile Organic Compounds. LAc71 to LAd34  - Revised
Section 2105.  Storage of Volatile Organic Components (Small Tanks). LAc60 NOT IN SIP
Section 2107.  Volatile Organic Compounds - Loading. LAc60 to LAd34 - Revised
Section 2108.  Marine Vapor Recovery. LAc71 to LAd34 - Revised
Section 2109.  Oil/Water - Separation. LAc64 to LAd34 - Revised
Section 2111.  Pumps and Compressors. LAc60
Section 2113.  Housekeeping. LAc60 to LAd34 - Revised
Section 2115.  Waste Gas Disposal. LAc64 to LAd34 - Revised
Section 2117.  Exemptions. LAc60 to LAd34 - Revised
Section 2119.  Variances. LAc60
Section 2121.  Fugitive Emission Control. LAc60 to LAd34 - Revised
Section 2122.  Fugitive Emission Control for Ozone Nonattainment Areas. LAc71 to LAd34 - Revised



Section 2101.  Compliance Schedules. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   All facilities affected by the regulations in this Chapter shall be in compliance as soon as practicable but in no event later than one year after becoming an affected facility, except for facilities affected by a different compliance schedule specified in an individual section of this Chapter.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:1084.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division in LR 13:741 (December 1987), amended LR 16:959 (November 1990).

********************** end section 2101 *******************86t**


Section 2103.  Storage of Volatile Organic Compounds. LAc71
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.  Revisions approved by EPA 07/25/96 (61 FR 38591) at 52.970(c)(64) effective 08/26/96; and 10/22/96 (61 FR 54748) at 52.970(c)(71) effective 12/23/96.

   A. No person shall place, store or hold in any stationary tank, reservoir or other container of more than 250 gallons (950 liters) and up to 40,000 gallons (151,400 liters) nominal capacity any volatile organic compound, having a true vapor pressure of 1.5 psia or greater at storage conditions, unless such tank, reservoir or other container is designed and equipped with a submerged fill pipe or a vapor loss control system or is    a pressure tank capable of maintaining working pressures sufficient at all times under normal operating conditions to prevent vapor or gas loss to the atmosphere.

   B. No person shall place, store or hold in any stationary tank, reservoir, or other container of more than 40,000 gallons (151,400 liters) nominal capacity any volatile organic compound having a true vapor pressure of 1.5 psia or greater at storage conditions unless such tank, reservoir, or other container is a pressure tank capable of maintaining working pressures sufficient at all times under normal operating conditions to prevent vapor or gas loss to the atmosphere or is designed and equipped with a submerged fill pipe and one or more of the vapor loss control devices described herein.

   C.  Internal Floating Roof.  An internal floating roof consists of a pontoon type roof, double deck type roof or internal floating cover which will rest or float on the surface of the liquid contents and is equipped with a closure seal to close the space between the roof edge and tank wall.  (In ozone nonattainment areas classified marginal or higher, this closure seal shall consist of either a liquid mounted primary seal, mechanical shoe seal, or two continuous seals mounted one above the other.)  All tank gauging and sampling devices shall be gas tight except when gauging or sampling is taking place.  Each opening (except rim space vents and automatic bleeder vents) shall be provided with a projection  below the liquid surface.  In addition, each opening (except for leg sleeves, bleeder vents, rim space vents, column wells, ladder wells, sample wells and stub drains) shall be provided with a cover equipped with a gasket.  Automatic bleeder vents and rim space vents shall be gasketed and ladder wells shall be equipped with a sliding cover.  This control equipment shall not be permitted if the organic compounds have a vapor pressure of 11.0 pounds per square inch absolute or greater under actual storage conditions.  If the internal floating roof does not meet the specifications of this rule, for internal floating roofs, then the specifications shall be met at either the first scheduled maintenance turnaround or no later than 10 years after the date of promulgation of this rule.  Any extension beyond the 10 year period, after the promulgation date shall be examined on a case-by-case basis and must be approved by the administrative authority*.

   D.  External Floating Roof.  An external floating roof consists of a pontoon type roof, double deck type roof or external floating cover which will rest or float on the surface of the liquid contents and is equipped with a closure seal to close the space between the roof edge and tank wall and a continuous secondary seal (a rim mounted secondary) extending from the floating roof to the tank wall.  This closure seal shall consist of a liquid mounted primary seal  or a mechanical shoe seal.  Installation of the closure seal shall be within the same time limitation as mentioned in Subsection C of this Section.

       1. A secondary seal is not required if:

           a. the tank is a welded tank storing a VOC with a vapor pressure at storage conditions less than 4.0 psia and is also equipped with liquid mounted primary seals, metallic type shoe seals, or equivalent

           b. the storage vessels are external floating roof tanks having nominal storage capacities of 420,000 gallons (1,589,900 liters) or less used to store produced crude oil or condensate prior to lease custody transfer.

           c. a metallic-type shoe seal is used in a welded tank which also has a secondary seal from the top of the shoe seal to the tank wall (i.e., a shoe-mounted secondary).

           d. an alternate seal or seals can be used in lieu of the primary and secondary seals required herein provided the resulting emission is not greater than that which would have resulted if the primary and secondary seals were installed.  The equivalency demonstration will be made to the satisfaction of the administrative authority*.

       2. The seal closure devices required in LAC 33:III.2103.D shall:

           a. have no visible holes, tears, or other openings in the seal(s) or seal(s) fabric.

           b. be intact and uniformly in place around the circumference of the floating roof and the tank wall.

           c. not have gap areas, of gaps exceeding 1/8 inch (0.32 cm) in width between the secondary seal and the tank wall, in excess of 1.0 in^2 per foot of tank diameter (6.5 cm^2 per 0.3m).

           d. not have gap areas, of gaps exceeding 1/8 in (0.32 cm) in width between the primary seal and the tank wall, in excess of 10.0 in^2 per foot of tank diameter (65 cm^2 per 0.3m).

           e.  the secondary seals shall be visually inspected at least semiannually.  The secondary seal gap measurements shall be made annually at any tank level provided the roof is off its legs.  The primary seal gap measurements shall be made every five years at any tank level provided the roof is off its legs.  Conditions not up to standards described in LAC 33:III.2103.D.2 shall be recorded along with date(s) that the standards are not met and the administrative authority shall be notified within seven days.  To avoid noncompliance with this Section, repairs necessary to be in compliance must be initiated within seven working days of recognition of defective conditions by ordering appropriate parts. Repairs shall be completed within three months of the ordering of the repair parts.  However, if it can be demonstrated that additional time for repair is needed, the administrative authority may extend this deadline.

       3. Requirements for Covering Openings.  All openings in the external floating roof, except for automatic bleeder vents, run space vent, and leg sleeves, are to provide a projection below the liquid surface.  The openings must be equipped with a gasketed cover, seal, or lid which must be in a closed position at all times except when the device is in actual use. Automatic bleeder vents must be closed at all times except when the roof is floated off or landed on the roof leg supports.  Rim vents must be set to open when the roof is being floated off the roof leg supports or at the manufacturer's recommended setting.  Any emergency roof drain must be equipped with a slotted membrane fabric cover or equivalent cover that covers at least 90 percent of the opening.

       4.  Requirements for Guide Poles and Stilling well Systems. Emissions from guide pole systems must be controlled for external floating roof storage tanks with a capacity greater than 40,000 gallons (approximately 151 m^3) and storing a liquid having a total vapor pressure of 1.5 psia or grater.  The description of the method of control and supporting calculations based upon the Addendum to American Petroleum Institute Publication Number 2517 Evaporative Loss from External Floating Roof Tanks (dated May 1994) shall be submitted to the administrative authority for approval prior to installation. Controls for nonslotted guide poles and stilling wells shall include pole wiper and gasketing between the well and sliding cover.  Controls for slotted guide poles shall include a float with wiper, pole wiper and gasketing between the well and sliding cover.  Alternate methods of controls are acceptable if demonstrated to be equivalent to the controls in this Section.  The administrative authority* must approve alternate methods of control.  Installation of controls required by this Subsection shall be required by November 15, 1996.  Requests for extension of the November 15, 1996, compliance date will be considered on a case-by-case basis for situations which require the tank to be removed from service to install the controls and must be approved by the administrative authority*.  The requirements of this Paragraph shall only apply in ozone nonattainment areas classified marginal or higher.  Controls systems required by this Subsection shall be inspected semiannually for rips, tears, visible gaps in the pole or float wiper, and/or missing sliding cover gaskets.  Any  rips, tears, visible gaps in the pole or float wiper, and/or missing sliding cover gaskets shall be repaired in accordance with this Section in order to avoid noncompliance with this Section.  Repairs necessary to be in compliance must be initiated within seven working days of identification by ordering appropriate parts.  Repairs shall be completed within three months of the ordering of the repair parts. However, if it can be demonstrated that additional time for repair is needed, the administrative authority may extend this deadline.

   E. Vapor Loss Control System.  A vapor loss control system consists of a gathering system capable of collecting the volatile organic compound vapors and a vapor disposal system capable of processing such organic vapors overall control efficiency of the vapor loss control system shall be a minimum of 95 percent.  All tank gauging and sampling devices shall be gas-tight except when gauging or sampling is taking place.

   F. No person shall place, store or hold in any stationary tank, reservoir or other container of more than 40,000 gallons (151,400 liters) nominal capacity any volatile organic compound having a true vapor pressure of 11 psia or greater at storage conditions unless such tank, reservoir or other container is a pressure tank capable of maintaining working pressures sufficient at all times under normal operating conditions to prevent vapor or gas loss to the atmosphere or is designed and equipped with a submerged fill pipe and vapor loss control system in accordance with LAC 33:III.2103.E.

   G.  Exemptions.  The provisions of this Section (i.e., LAC 33:III.2103) do not apply to:
       1.  existing and new storage tanks, located in any parish other than those classified as marginal and above ozone nonattainment parishes, used for crude or condensate and having a nominal storage capacity of less than 420,000 gallons (1,589,900 liters) unless such new tanks are subject to New Source Performance Standards;
       2.  tanks 420,000 gallons (1,589,900 liters) or greater in the attainment parishes used to store produced crude oil or condensate prior to lease custody transfer unless such tanks are subject to New Source Performance Standards;
       3.  for the marginal and above nonattainment parishes, existing and new storage tanks that are used for crude or condensate prior to lease custody transfer and that have a nominal storage capacity of less than 420,000 gallons (1,589,900 liters) unless such new tanks are subject to New Source Performance Standards;
       4.  JP-4 fuels stored in horizontal underground tanks.

   H. Compliance Tests

       1. Floating Roofs.  The seal gap area shall be determined by measuring the length and width of the gaps around the entire circumference of the seal.  A 1/8 inch (0.32 cm) uniform diameter probe shall be used for measuring gaps.  Only gaps greater than or equal to 1/8 inch (0.32 cm) shall be used in computing the gap area. The area of the gaps shall be accumulated to determine compliance with LAC 33:III.2103.D.2.c and d.  Compliance with the other provisions specified in LAC 33:III.2103.D.2.a and b and D.4 may be determined by visual inspection.

       2. Add-On Control Devices.  The following test methods shall be used, where appropriate to measure control device compliance:

           a. Test Methods 1 through 4 (LAC 33:III.6001, 6003, 6009 and 6013, respectively) for determining flow rates, as necessary;

           b. Test Method 18 (LAC 33:III.6071) for measuring gaseous organic compound emissions by gas chromatographic analysis;

           c. Test Method 21 (LAC 33:III.6077) for determination of volatile organic compound leaks;

           d. Test Method 25 (LAC 33:III.6085) for determining total gaseous nonmethane organic emissions as carbon;

           e. Additional performance test procedures, or equivalent test methods, approved by the administrative authority*.

       3.  Vapor Pressure.  True vapor pressure shall be determined by ASTM Test Method D323-82 for the measurement of Reid vapor pressure, adjusted for actual storage temperature in accordance with API Publication 2517, Third Edition, 1989.

   I.  Monitoring/Recordkeeping/Reporting.  The owner/operator of any storage facility shall maintain records to verify compliance with or exemption from LAC 33:III.2103.  The records shall be maintained for at least two years and will include, but not be limited to, the following:

       1.  the results of inspections required by LAC 33:III.2103.D.2.e. and D.4 shall be recorded.

       2.  for vapor loss control systems (LAC 33:III.2103.E) the following information shall be recorded:

           a.  daily measurements of the exhaust gas temperature immediately downstream of a direct-flame incinerator;

           b.  daily measurements of the inlet and outlet temperature of a chiller, or catalytic incinerator;

           c.  results of monitoring outlet VOC concentration of carbon adsorption bed to detect breakthrough.

       3.  the date and reason for any maintenance and repair of the applicable control devices and the estimated quantity and duration of volatile organic compound emissions during such activities.

       4.  the results of any testing conducted in accordance with the provisions specified in LAC 33:III.2103.H.

       5.  records of the type(s) of VOC stored and the average monthly true vapor pressure of the stored liquid for any storage vessel with an external floating roof that is exempt from the requirements for a secondary seal and is used to store VOCs with a true vapor pressure greater than 1.0 psia.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:1084.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division, LR 13:741 (December 1987), amended LR 16:23 (January 1990), amended by the Office of Air Quality and Radiation Protection, Air quality Division, LR 17:360 (April 1991), LR 18:1121 (October 1992), LR 20:1376 (December 1994), LR 21:1223 (November 1995), LR 21:1333 (December 1995).

********************** end section 2103 ********************86t**
This SIP Citation Was Last Modified on: 06/20/98

Section 2105.  Storage of Volatile Organic Components (Small Tanks). NOT IN SIP LAc60

NOT IN SIP - See 40 CFR 52.970(c)(60)(i)(A)

***************** end section 2105 *****************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2107.  Volatile Organic Compounds - Loading. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   A. Applicability. The following loading facilities for volatile organic compounds having a true vapor pressure at loading conditions of 1.5 psia (10.3 kPa) or greater must comply with the requirements of Subsections B through F when servicing tanks, trucks or trailers which have individual capacities in excess of 200 gallons (760 liters):

       1. 20,000 gallons (75,700 liters) or more throughput per day (averaged over any 30-day period), for operations (all facilities on premises) for which construction commenced after May 20, 1979; or

       2. 40,000 gallons (151,400 liters) or more throughput per day (averaged over any 30-day period), for operations (all facilities on premises) for which construction commenced prior to May 20, 1979.  Once a facility is subject to this Section, it must remain in compliance with the requirements of Subsections B through F, even during periods in which its throughput is below the applicability levels.

   B. Control Requirements. The facility must be equipped with a vapor collection system properly installed, and in good working order.  The vapor collection system shall consist of, at a minimum, a vapor return line which returns to the VOC dispensing vessel or to a disposal system all vapors displaced during loading.  In the event a disposal system is used, it shall have a destruction/removal efficiency as referenced at Subsection E (demonstrated to the satisfaction of the Louisiana Department of Environmental Quality) of no less than 90 percent. Examples of vapor disposal systems include but are not limited to incinerators, flares, carbon adsorbers or chillers.
   Provisions must be made to prevent spills during the attachment and disconnection of filling lines or arms.  Loading and vapor lines must be equipped with fittings which close automatically when disconnected, or must be equipped to permit residual VOC in the loading line to discharge into a collection system or disposal or recycling system.

   C. Monitoring. No liquid or gaseous leaks shall exist during loading or unloading operations.  Inspection for visible liquid leaks, visible fumes, or significant odors resulting from VOC dispensing operations shall be conducted by the owner or operator of the VOC loading facility or the owner or operator of the tank, truck, or trailer.  VOC loading or unloading through the affected transfer lines shall be discontinued immediately when a leak is observed and shall not be resumed until the observed leak is repaired.

   D. Recordkeeping.  The owner or operator of any VOC loading facility shall maintain the following information on the premises for at least two years and shall make such information available to representatives of the Louisiana Department of Environmental Quality upon request:

      1. a daily record of the total throughput of VOC loaded at the facility; and

      2. for VOC loading operations subject to the requirements of this Section:

           a. a daily record of the number of delivery vessels loaded at the facility and the quantity and type of VOC loaded to each delivery vessel;

           b. a record of any leaks found at the facility in accordance with the provisions specified in Subsection C of this Section and the corrective action taken;

           c. a record of the results of any testing conducted at the facility in accordance with the provisions specified in Subsection E of this Section.

      3.  For vapor disposal systems, the following information shall be recorded:

           a.  daily measurements of the exhaust gas temperature immediately downstream of a direct-flame incinerator;

           b.  daily measurements of the inlet and outlet temperature of a chiller or catalytic incinerator; and

           c.  breakthrough of VOCs in a carbon adsorption unit.

      4.  The date and reason for any maintenance and repair of the applicable control devices and the estimated quantity and duration of volatile organic compound emissions during such activities shall be recorded.

   E. Test Methods. Compliance with Subsection B of this Section shall be determined by applying the following test methods, as appropriate:

      1. Test Methods 1-4 (LAC 33:III.6001, 6003, 6009 and 6113, respectively) for determining flow rates, as necessary;
      2. Test Method 25 (LAC 33:III.6085) for determining total gaseous nonmethane organic emissions as carbon.

   F. Exemptions.  This Section does not apply to a) crude or condensate loading facilities, b) ship and barge loading operations, and c) gasoline loading facilities which are regulated under Subchapter F.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division, LR 13:741 (December 1987), amended LR 16:116 (February 1990), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, LR 17:360 (April 1991).

********************** end section 2107 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2108.  Marine Vapor Recovery. LAc71
Approved by EPA 10/22/96 (61 FR 54748) at 52.970(c)(71) effective 12/23/96.

  A.  Applicability

  An affected facility is any marine loading operation serving ships and/or barges loading crude oil, gasoline or volatile organic compounds (VOCs) with an uncontrolled emission of 100 tons per year or greater of volatile organic compounds having a true vapor pressure of 1.5 psia or greater at the loading temperature of the liquid.


  B.  Definitions

  Terms used in this Section are defined in LAC 33:III.111 of these regulations with the exception of those terms specifically defined below as follows:
  Barge means a tank barge which is a tank vessel not equipped with means of self-propulsion especially constructed or converted to carry liquid bulk cargo in tanks.

  Crude Oil means a natural hydrocarbon mixture, that is, petroleum in its unrefined state.

  Gasoline means any petroleum distillate or petroleum distillate/alcohol blend having a Reid vapor pressure of 27.6 kilopascals or greater which is used as a fuel for internal combustion engines.

  Ship means a tankship which is a tank vessel self-propelled by power especially constructed or converted to carry liquid bulk cargo in tanks.


  C.  On or after the date specified in LAC 33:III.2108.D.

    1.  Each affected facility shall be equipped with a vapor collection system designed to collect the organic compounds vapors displaced from ships and/or barges during loading.

    2.  The vapors shall be collected and processed by a recovery and/or destruction system such that uncontrolled emissions (identified in LAC 33:III.2108.A) are reduced by at least 90 percent by weight.

    3.  The emissions to the atmosphere caused by the loading of crude oil, gasoline or volatile organic compounds into ships and/or barges are not to exceed the following:
      a.  for barge loading of gasoline - 70 mg of total organic compounds per liter of VOC's loaded (0.6 pounds/1,000 gallons)
      b.  for barge loading of crude oil or other VOC's - 30 mg of total organic compounds per liter of VOC's loaded (0.25 pounds/1,000 gallons).
      c.  for ship loading of gasoline - 30 mg/liter of VOC's loaded (0.25 pounds/1,000 gallons).
      d.  for ship loading of crude oil or other VOC's - 12 mg/liter of VOC's loaded (0.1 pounds/1,000 gallons).

    4.  Alternate procedures to those described in LAC 33:III.2108.C.1, C.2 and C.3 may be used provided:
      a.  the procedure results in at least a 90 percent by weight reduction in uncontrolled emissions and
      b.  the administrative authority has granted approval of the installation prior to any commencement of construction.

    5.  The owner or operator of the affected facility shall act to assure that loadings are made only into ships and/or barges equipped with vapor collection equipment that is compatible with the affected facility's vapor collection system.

    6.  The owner or operator of the affected facility shall act to assure that the vapor collection and disposal system is properly connected to the ships and/or barges before any loading is done.


  D.1. For loadings of gasoline and other VOCs, except crude oil, each affected facility shall be in compliance with the provisions of this Section as expeditiously as practicable but no later than December 31, 1991.  After December 31, 1991, an affected facility shall only be permitted to exceed the emissions to the atmosphere set forth in Section 2108.C.3 caused by the loading into ships or barges of gasoline and other VOCs except crude oil if:
      a.  the barge or ship is not equipped with vapor collection equipment;
      b.  the last internal inspection of the ship or barge listed on its certificate of inspection was prior to July 23, 1990; and
      c.  the loading which results in the excess emissions occurs before May 1, 1994.

    2.  For crude oil loadings, each affected facility shall be in compliance with the provisions of this Section as expeditiously as practicable but no later than May 1, 1992.  After May 1, 1992, an affected facility shall only be permitted to exceed the emissions to the atmosphere set forth in Section 2108.C.3 caused by the loading into ships or barges of crude oil if:
      a.  the barge or ship is not equipped with vapor collection equipment;
      b.  the last internal inspection of the ship or barge listed on its certificate of inspection was prior to July 23, 1990; and
      c.  the loading which results in the excess emissions occurs before May 1, 1994.

    3.  Any request for an extension of the compliance dates will be considered on a case-by-case basis in response to a written request to the administrative authority and in accordance with LAC 33:III.2119.


  E.  Test Methods and Procedure

    1.  For the purpose of determining compliance with the mass emission limitations of LAC 33:III.2108.C.3 the following reference methods shall be used:
      a.  for the determination of volume at the exhaust vent:
        i.  Method 2B for combustion vapor processing systems (except flare stacks).
        ii.  Method 2A for all other vapor processing systems.
      b.  for the determination of total organic compounds concentration at the exhaust vent, Method 25A or 25B.  The calibration gas shall be either propane or butane.

    2.  Vapor processing systems utilizing a flare stack to destruct the collected VOC's will be exempt from testing and must be designed and operated in accordance with LAC 33:III.3741.D.

    3.  Immediately prior to the performance test for determination of compliance, all potential sources of vapor leakage in the facility's vapor collection system equipment shall be monitored for leaks using Method 21.  The monitoring shall be conducted only while a ship or barge is being loaded and should cover all parts of the vapor system, including tank hatches, that operate at pressures above atmospheric pressure.  All leaks shall be repaired prior to conducting the performance test.

    4.  The test procedure for determining compliance with LAC 33:III.2108.C.3 shall be that specified below:
      a.  All testing equipment shall be prepared and installed as specified in the appropriate test methods.
      b.  The time period for a performance test shall be not less than three hours.  As much as possible, testing should be conducted during the three-hour period in which the highest emissions normally occur (near the end of the loading).
      c.  For intermittent vapor processing systems:
        i.  the vapor holder level shall be recorded at the start of the performance test.  The end of the performance test shall coincide with a time when the vapor holder is at its original level;
        ii.  at least two startups and shutdowns of the vapor processor shall occur during the performance test.  If this does not occur under automatically-controlled operation, the system shall be manually controlled.
      d.  The volume of crude oil, gasoline and volatile organic compounds loaded during the performance test period, whose vapor emissions are controlled by the processing system being tested, shall be determined.
      e.  An emission testing interval shall consist of each five-minute period during the performance test.  For each interval:
        i.  the reading from each measurement instrument shall be recorded, and
        ii.  the volume exhausted and the average total organic compounds concentration in the exhaust vent shall be determined, as specified in the appropriate test method.  The average  total organic compounds concentration shall correspond to the volume measurement by taking into account the sampling system response time.
      f.  The mass emitted during each testing interval shall be calculated as follows:

  Mei = (10^-6)(K)(Ves)(Ce)

  where:
    Mei = mass of total organic compounds emitted during testing interval i, mg.
    Ves = volume of air-vapor mixture exhausted, m^3, at standard conditions.
    Ce = total organic compounds concentration (as measured) at the exhaust vent, ppmv.
    K = density of calibration gas, mg/m^3, at standard conditions.
      = 1.83 x 10^6 for propane
      = 2.41 x 10^6 for butane.
    s = standard conditions, 20 degrees C and 760 mm Hg.


      g.  The total organic compounds mass emissions shall be
calculated as follows:

      Sum from i = 1 to n {Mei}
  E = --------------------------
               L
  where:
    E = mass of total organic compounds emitted per volume of crude oil, gasoline and volatile organic compounds loaded, mg./liter.
    Mei = mass of total organic compounds emitted during testing interval i, mg.
    L = total volume of crude oil, gasoline and volatile organic compounds loaded, liters.
    n = number of testing intervals.

    5.   The owner or operator may adjust the emission results to exclude the methane and ethane content in the exhaust vent by the chromatographic method shown in Method 25.


  F.  Reporting and Recordkeeping

    1. The results of any testing done in accordance with LAC 33:III.2108.E. shall be reported to the administrative authority within 45 days of the test.

    2.  The following records shall be kept on file at the affected facility for at least two years and shall be made available for inspection by a representative of the administrative authority on request:
      a.  Daily throughput of liquid by type.
      b.  Daily record of the number of each type of vessel loaded and the type and quantity of each liquid loaded on each vessel.
      c.  Records of all replacements or additions of components performed on the vapor processing system.
      d.  Records on control equipment operating parameters such as monitoring for breakthrough on carbon adsorption devices, pump amperes and temperatures in refrigeration systems.
      e.  If any loadings are conducted which result in emissions exceeding those listed in Section 2108.C.3  a record of the name, owner, type and quantity of liquid loaded, the date of loading and the vessel's last internal examination dates listed on its certificate of inspection shall be maintained for three years.


  G.  Operation and Maintenance
    1.  No person may load gasoline, crude oil or other VOCs into ships or barges at affected facilities unless all loading and vapor lines, arms and hoses are equipped with fittings which make vapor-tight connections and provide tight shut-off when disconnected.
    2.  Provisions must be made to prevent spills or leaks during attachment or disconnection of filling lines, hoses or arms.  Liquids subject to this rule shall not be spilled or handled in any other manner that would result in evaporation to the atmosphere.
    3.  All equipment associated with the loading of gasoline, crude oil or other VOC's into ships or barges at affected facilities shall be maintained to be leak-free, gas-tight and in good working order.


  H.  Safety/Emergency
    Nothing in this rule shall be construed to:
    1.  require any act or omission that would be in violation of any regulation or other requirement of the United States Coast Guard or;
    2.  prevent any act or omission that is necessary to secure the safety of a vessel or for saving life at sea.

  AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
  HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Radiation Protection, Air Quality Division, LR 14:704 (October 1988), as amended LR 16:959 (November 1990).

********************** end section 2108 *******************86t**
This SIP Citation Was Last Modified on: 06/20/98

Section 2109.  Oil/Water - Separation. LAc64
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.  Revisions approved by EPA 07/25/96 (61 FR 38591) at 52.970(c)(64) effective 08/26/96.

   A.  Oil/Water - Separation. Single or multiple compartment volatile organic compound water separators which receive effluent water from any equipment processing, refining, treating, storing, or handling volatile organic compounds shall be equipped with one of the following vapor loss control devices properly installed, in good working order and in operation:

       1.  a container having all openings sealed and totally enclosed liquid contents. All gauging and sampling devices will be gas-tight except when gauging or sampling is taking place.

       2.  a container equipped with a floating roof, consisting of a pontoon type, double deck type roof, or internal floating cover which rests or floats on the surface of the contents and is equipped with a closure seal or seals to close the space between the roof edge and container wall. All gauging and sampling devices will be gas-tight except when gauging or sampling is taking place.

       3.  a container equipped with a vapor disposal system capable of processing such organic vapors and gases so as to limit their emission to the atmosphere to the same extent as LAC 33:III.2109.A.1 and 2 and with all container gauging and sampling devices gas-tight except when gauging or sampling is taking place.

       4.  other equivalent equipment or means as may be approved by the administrative authority*.

   B.  Exemptions from LAC 33:III.2109.A

       1.  Volatile organic compound water separators used exclusively in conjunction with the production of crude oil or condensate are exempt from the provisions of LAC 33:III.2109.A.

       2.  Any single or multiple compartment volatile organic compound water separator which separates less than 200 gallons (757 liters) a day of materials containing volatile organic compounds.

       3.  Any single or multiple compartment volatile organic compound water separator which separates materials having a true vapor pressure of volatile organic compounds less than 0.5 psia (3.4 kPa).

       4.  Except for the parishes of Ascension, Calcasieu, East Baton Rouge, Iberville, Livingston, Pointe Coupee, and West Baton Rouge, any single- or multiple-compartment volatile organic compound water separator emitting 100 tons per year or less of regulated hydrocarbons (uncontrolled) is exempt from the provisions of LAC 33:III.2109.A.

       5.  Any facility may choose to reduce the flow of volatile organic compounds to the oil-water separator by process or equipment modifications at the source(s) as an alternate to the requirements of LAC 33:III.2109.A.  Such alternate means of compliance must be shown to result in a reduction of VOC emissions at least as great as would result from application of the measures specified in LAC 33:III.2109.A.

   C.  Compliance.  Compliance with LAC 33:III.2109.A shall be determined by monthly visual inspections or by use of one of the following test methods where appropriate:

       1.  Test Method 1 through 4 (LAC 33:III.6001, 6003, 6009 and 6013, respectively) for determining flow rates, as necessary;

       2.  Test Method 18 (LAC 33:III.6071) for measuring gaseous organic compound emissions by gas chromatographic analysis;

       3.  Test Method 21 (LAC 33:III.6077) for determination of volatile organic compound leaks;

       4.  Test Method 25 (LAC 33:III.6085) for determining total gaseous nonmethane organic emissions as carbon;

       5.  determination of true vapor pressure using ASTM Test Method D323-82 for the measurement of Reid vapor pressure, adjusted for actual storage temperature in accordance with API Publication 2517, Third Edition, 1989; or

       6.  additional performance test procedures, or equivalent test methods, approved by the administrative authority*.

   D.  Recordkeeping.  The owner/operator of any single or multiple compartment volatile organic compound water separator shall maintain records to verify compliance with or exemption from LAC 33:III.2109.  The records shall be maintained for at least two years and will include but not be limited to the following:

       1.  results of the monthly visual inspections and the results of other tests performed in accordance with LAC 33:III.2109.C;

       2.  measurement of the volume and true vapor pressure of the volatile organic compound(s) recovered by the separator to demonstrate continuous compliance with the criteria for exempted facilities;

       3.  the date and reason for any maintenance and repair of the applicable control devices.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division, LR 13:741 (December 1987), amended LR 16:116 (February 1990), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, LR 17:360 (April 1991), LR 18:1122 (October 1992).

********************** end section 2109 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2111.  Pumps and Compressors. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   All rotary pumps and compressors handling volatile organic compounds having a true vapor pressure of 1.5 psia or greater at handling conditions shall be equipped with mechanical seals or other equivalent equipment or means as may be approved by the administrative authority*.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division in LR 13:741 (December 1987), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, in LR 17:360 (April 1991).

********************** end section 2111 *******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2113.  Housekeeping. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   Best practical housekeeping and maintenance practices must be maintained at the highest possible standards to reduce the quantity of organic compounds emissions. Emission of organic compounds must be reduced wherever feasible.

   A.  Good housekeeping shall include but not be limited to the following practices:

       1.  Spills of volatile organic compounds shall be avoided and clean up of such spills shall employ procedures that reduce or eliminate the emission of volatile organic compounds.

       2.  Containers of volatile organic compounds shall not be left open and the contents allowed to evaporate.

       3.  Waste materials that contain volatile organic compounds shall be stored and disposed of in a manner that reduces or eliminates the emission of volatile organic compounds.

       4.  Each facility shall develop a written plan for housekeeping and maintenance that places emphasis on the prevention or reduction of volatile organic compound emissions from the facility.  This plan shall be submitted to the Air Quality Division as a part of the information package accompanying a permit application for a new facility or major modification or at any other time as requested.  A copy shall be kept at the facility, if practical, or at an alternate site approved by the Air Quality Division.

       5.  Good housekeeping shall be determined by compliance with LAC 33:III.2121 (Fugitive Emission Control) and the maintenance and the housekeeping plan required by LAC 33:III.2113.A.4.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division in LR 13:741 (December 1987), amended LR 16:116 (February 1990), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, LR 17:360 (April 1991).

********************** end section 2113 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2115.  Waste Gas Disposal. LAc64
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.  Revisions approved by EPA 07/25/96 (61 FR 38591) at 52.970(c)(64) effective 08/26/96.

   Any waste gas disposal stream containing volatile organic compounds (VOC) from any emission source including those emissions from process unit upsets, start-ups and shutdowns shall be controlled by one of the following methods:

   A.  Operations Which Commenced Construction Prior to January 20, 1985.  Nonhalogenated hydrocarbons shall be burned at 1300 degrees F (704 degrees C) for 0.3 second or greater in a direct-flame afterburner or an equally effective device which achieves a removal efficiency of 95 percent or greater, as determined in accordance with LAC 33:III.2115.J.1, or if emissions are reduced to 50 ppm by volume, whichever is less stringent.

   B.  Operations Which Commenced Construction on or after January 20, 1985. Nonhalogenated hydrocarbons shall be burned at 1600 degrees F (870 degrees C) for 0.5 second or greater in a direct-flame afterburner or thermal incinerator.  Other devices will be  accepted provided 98 percent or greater VOC destruction or removal efficiency can be demonstrated, as determined in accordance with LAC 33:III.2115.J.1, or if emissions are reduced to 20 ppm by volume, whichever is less stringent.

   C.  All waste gas disposal streams containing VOC at the following sources in existing polypropylene plants using liquid phase processes shall be controlled as specified in LAC 33:III.2115.B above:

       1.  polymerization reaction section (i.e., reactor vents);

       2.  material recovery section (i.e., decanter vents, neutralizer vents, by-product and diluent recovery operation vents); and

       3.  product finishing section (i.e., dryer vents and extrusion and pelletizing vents).

   D.  All waste gas disposal streams containing VOC at the following sources in existing high-density polyethylene plants using liquid phase slurry processes shall be controlled as specified in LAC 33:III.2115.B above:

       1.  material recovery section (i.e., ethylene recycle treater vents), and

       2.  product finishing section (i.e., dryer vents and continuous mixer vents).

   E.  For polystyrene plants using continuous processes, the emissions from the material recovery section (i.e., product devolatilizer system) shall be limited to 0.12 kg VOC/1,000 kg of product.

   F.  The halogenated hydrocarbons shall be combusted or controlled by other methods specified in G below which achieve a removal efficiency of 95% or greater, as determined in accordance with LAC 33:III.2115.J.1.  If combusted, the halogenated products of combustion shall be reduced to an emission level acceptable to the administrative authority.

   G.  Other methods of control (such as, but not limited to, carbon adsorption, refrigeration, catalytic and/or thermal reaction, secondary steam stripping, recycling or vapor recovery system) may be substituted for burning provided the substitute is acceptable to the administrative authority* and it achieves the same removal efficiency as required by this Section and determined in accordance with LAC 33:III.2115.J.1 or it achieves a degree of control not practically or safely achieved by other means.


  H.  Exemptions

    1.  All waste gas disposal streams containing VOC, except those subject to Subsections C, D and E of this Section, are exempt from the requirements of this Section if any of the following conditions are met:
      a.  it can be demonstrated that the waste gas stream is not a part of a facility with total VOC emissions greater than or equal to 50 TPY in the parishes of Ascension, East Baton Rouge, Iberville, Livingston, Pointe Coupee and West Baton Rouge, or 100 TPY in any other parish; or
      b.  it is a vent gas stream from a low-density polyethylene plant and no mare than 1.1 pounds of ethylene per 1,000 pounds (1.1 kg/1000 kg) of product are emitted from all the vent gas streams associated with the formation, handling and storage of solidified product; or
      c.  it is a vent gas stream having a combined weight of VOC equal to or less than 100 pounds (45.4 kg) in any continuous 24-hour period; or
      d.  it is a vent gas stream with a concentration of VOC less than 0.44 psia true partial pressure (30,000 ppm) except for the parishes of Ascension, Calcasieu, East Baton Rouge, Iberville, Livingston, Pointe Coupee, St. James and West Baton rouge in which the concentration of VOC in the vent gas stream  must be less than 0.044 psia true partial pressure (3,000 ppm).

    2.  Except for waste gas disposal streams subject to Subsections C, D and E of this Section, the administrative authority* may waive the requirements of this Section if one of the following conditions is met:
      a.  it will not support combustion without economically impractical amounts of auxiliary fuel; or
      b.  its disposal cannot be practically or safely accomplished by the means described herein or other equivalent means without causing undue economic hardship.

    3.  Waste gas disposal streams subject to Subsections C, D and E of this Section are exempt from the requirements of this Section if it can be demonstrated that the waste gas disposal stream has a concentration of VOC no greater than 408 ppm by volume.


   I.  Test Methods.  Compliance with paragraphs A, B, C, D, E, F, and G of this Section shall be determined by applying the following test methods, as appropriate:

       1.  Test Methods 1 - 4 (LAC 33:III.6001, 6003, 6009, and 6013, respectively) for determining flow rates, as necessary;

       2.  Test Method 18 (LAC 33:III.6071) for determining gaseous organic compounds emissions by gas chromatography.

       3.  Test Method 25 (LAC 33:III.6085) for determining total gaseous nonmethane organic emissions as carbon;

       4.  Test Method 25A or 25B (LAC 33:III.6086 or 6087) for determining total gaseous organic concentration using flame ionization or nondispersive infrared analysis; and

       5.  modified test methods approved or specified by the administrative authority*.


   J.  Compliance.  All facilities affected by LAC 33:III.2115 shall be in compliance as soon as practicable but in no event later than two years after becoming an affected facility, except for the parishes of Ascension, Calcasieu, East Baton Rouge, Iberville, Pointe Coupee, St. James and West Baton Rouge where facilities shall be in compliance no later than one year after becoming an affected facility.

       1.  Compliance with Section 2115 shall be demonstrated at the owner/operator's expense as requested by the administrative authority.  Such demonstration shall consist of control device destruction efficiency or recovery efficiency testing.  Such compliance testing is in addition to the continuous monitoring required under LAC 33:III.2115.J.2.

       2.  The owner/operator of any facility subject to LAC 33:III.2115 shall install and maintain monitors to accurately measure and record operational parameters of all required control devices as necessary to ensure the proper functioning of those devices in accordance with the design specifications, including but not limited to:

           a.  the exhaust gas temperature of direct flame incinerators and/or the gas temperature immediately upstream and downstream of any catalyst bed;
           b.  the breakthrough of volatile organic compounds in a carbon adsorption unit;

           c.  the total amount of volatile organic compounds recovered by carbon adsorption or other waste gas stream recovery systems during a calendar month;

           d.  the dates for any maintenance of the required control devices and the estimated quantity and duration of volatile organic compound emissions during such activities; and

           e.  any other parameters affecting or related to waste gas streams as considered necessary by the administrative authority.


   K.  Recordkeeping.  The owner or operator of any facility subject to LAC 33:III.2115 shall maintain the following information on the premises for at least two years and shall make such information available to representatives of the Louisiana Department of Environmental Quality and the Environmental Protection Agency upon request:

       1.  a record for each vent of the results of any testing conducted at the facility in accordance with the provisions specified in Paragraph I and J of this Section;

       2.  the date for any maintenance and repair of required control devices and the estimated quantity and duration of volatile organic compound emissions during such activities;

       3.  records for each vent required to satisfy the provisions of LAC 33:III.2115.J.2 to demonstrate the proper functioning of applicable control equipment to design specifications;

       4.  records to demonstrate that the criteria are being met for any exemption claimed (such as daily records of VOC waste gas stream throughput or concentrations).

   L.  LAC 33:III.2115 does not apply to safety relief and vapor blowdown systems where control cannot be accomplished because of safety or economic considerations.  However, the emissions from these systems shall be reported to the department as required under LAC 33:III.917.  Emergency occurrences shall be reported under LAC 33:III.927.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division, LR 13:741 (December 1987), amended LR 16:959 (November 1990), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, LR 17:654 (July 1991), LR 18:1122 (October 1992), LR 19:317 (March 1993).

********************** end section 2115 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2117.  Exemptions. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   The following compounds are exempt from the control requirements of
LAC 33:III.2101 to 2147:
methane,
ethane,
1,1,1 trichloroethane (methyl chloroform),
methylene chloride (dichloromethane),
trichlorofluoromethane (CFC-11),
dichlorodifluoromethane (CFC-12),
chlorodifluoromethane (CFC-22),
trichlorotrifluoroethane (CFC-113),
trifluoromethane (FC-23),
dichlorotetrafluoroethane (CFC-114),
chloropentafluoroethane (CFC-115),
dichlorotrifluroethane (HCFC-123),
tetrafluoroethane (HFC-134a),
dichlorofluoroethane (HCFC-141b), and
chlorodifluoroethane (HCFC-142b).

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.

   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division in LR 13:741 (December 1987), amended LR 16:116 (February 1990).

********************** end section 2117 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2119.  Variances. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   A.  If upon written application of responsible person(s) the administrative authority* finds that by reason of exceptional circumstances strict conformity with any provisions of these regulations would cause undue hardship, would be unreasonable, impractical or not feasible technologically or economically under the circumstances, the administrative authority* may permit a variance from these regulations upon such conditions and with such time limitations as it may prescribe for prevention, control, or abatement of air pollution in harmony with the intent of the Act.

   B.  No variance may permit or authorize the maintenance of a nuisance, or a danger to the public health or safety.

   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division in LR 13:741 (December 1987), amended LR 16:116 (February 1990), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, LR 17:360 (April 1991).

********************** end section 2119 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2121. Fugitive Emission Control. LAc60
Approved by EPA 05/05/94 (59 FR 23166) at 52.970(c)(60) effective 06/06/94.

   A.  Applicability. This regulation is applicable to equipment in petroleum refineries, natural gas processing plants, the synthetic organic chemical manufacturing industry (SOCMI), the methyl tertiary butyl ether (MTBE) manufacturing industry, and the polymer manufacturing industry.

   B.  Fugitive Emission Control Requirements

       1.  No component shall be allowed to leak organic compounds exceeding 10,000 parts per million by volume (ppmv), as defined in LAC 33:III.111, when tested by Method 21 "Determination of Volatile Organic Compound Leaks" in the Division's Source Test Manual.
       Any regulated component observed leaking by sight, sound, or smell must be repaired according to 2121.B.3, regardless of the leak's concentration.  This includes flange and connection leaks found per 2121.C.3.b, pump and compressor seal leaks found during the weekly visual inspections, and any other regulated component found leaking.

       2.  No valve, except safety pressure relief valves, valves on sample lines, valves on drain lines and valves that can be removed and replaced without a shutdown, shall be located at the end of a pipe or line containing volatile organic compounds unless the end of such line is sealed with a second valve, a blind flange, a plug, or a cap. Such sealing devices may be removed only when the line is in use, for example, when a sample is being taken. When the line has been used and is subsequently resealed, the upstream valve shall be closed first, followed by the sealing device.

       3.  The operator shall make every reasonable effort to repair a leaking component, as described in LAC 33:III.2121.B within 15 days. If the component can be isolated or bypassed so as to significantly reduce or eliminate leakage, or if the repair of a component would require a unit shutdown, and if the shutdown would create more emissions than the repair would eliminate, the repair may be delayed to the next scheduled shutdown. An early unit shutdown may be ordered if leaking component losses become excessive.

   C.  Monitoring Requirements. The monitoring of the affected components shall be performed by the following schedule using the method described in LAC 33:III.2121.B:

       1.  Petroleum Refineries, SOCMI, MTBE, and Polymer Manufacturing Industry:

           a.  Monitor with a leak detection device one time per year (annually) the following items:

              i.  pump seals;
              ii.  pipeline valves in liquid service; and
              iii.  process drains.

           b.  Monitor with a leak detection device four times per year (quarterly) the following items:
              i.  compressor seals;
              ii.  pipeline valves in gas service;
              iii.  pressure relief valves in gas service;
              iv.  valves in light liquid service at SOCMI, MTBE, and Polymer Manufacturing Plants,
              v. pumps in light liquid service at SOCMI, MTBE, and Polymer Manufacturing Plants, and
              vi. valves in gas service at SOCMI, MTBE, and Polymer Manufacturing Plants.

           c.  Monitor pump seals visually 52 times a year (weekly).
       2.  Natural gas processing plants:

           a.  Monitor pump seals and compressor seals visually 52 times a year (weekly).

           b.  Monitor with a leak detection device four times a year (quarterly):

              i.  pumps, pump and compressor seals;
              ii.  valves; and
              iii.  pressure relief valves in gas service.

       3.  All listed in Paragraphs 1 and 2 above.

           a.  Monitor with a leak detection device any pressure relief valve within 24 hours after it has vented to the atmosphere (For natural gas processing plants an immediate visual evaluation will be made).

           b.  Monitor immediately with a leak detection device any component that appears to be leaking on the basis of sight, smell, or sound. In lieu of monitoring, the operator may elect to implement actions as specified in LAC 33:III.2121.B.

       4.  Exemptions. Monitoring is not required on the following:

           a.  components subject to LAC 33:III.2121.C.1 (petroleum refineries, SOCMI, MTBE, and polymer  manufacturing industry) which contact a process fluid that contains less than 10 percent VOC by volume or components subject to LAC 33:III.2121.C.2 (Natural Gas Processing Plants) which contact a process fluid that contains less than 1.0 percent VOC by weight.

           b.  components in the petroleum refineries, SOCMI, MTBE, and polymer manufacturing industry which contact only a process liquid containing a VOC having a true vapor pressure equal to or less than 0.0435 psia (0.3 kPa) at 68 degrees F (20 degrees C).

           c.  pipeline flanges, inaccessible valves, valves that are unsafe to monitor, check valves (including similar devices not externally regulated).  Inaccessible valves should be monitored on an annual basis at a minimum.  Unsafe-to-monitor valves should be monitored when conditions would allow these valves to be monitored safely, e.g., during shutdown.

           d.  pressure relief valves in liquid service at SOCMI and Polymer Manufacturing Industry, except after venting.
           e.  pressure relief devices, pump seals or packing and compressor seals or packing which are tied to either a flare header or vapor recovery device.

           f.  equipment operating under vacuum.

           g.  natural gas processing plants with less than 40 million cubic feet per day (mmcfd) capacity that do not fractionate natural gas liquids.

           h.  components contacting organic compounds exempted under LAC 33:III.2117 or mixtures of same with water.

           i.  pumps and compressors with double mechanical seal.

           j.  research and development pilot facilities and small facilities with less than 100 valves in gas or liquid service.

        5.  Alternate Monitoring Program. Any facility which already has in place a fugitive emission monitoring program which controls to a higher degree than required under this Section shall be exempted from this Section upon submittal of a description of the program to the administrative authority*.

   D.  Alternate Control Techniques. The monitoring schedule in LAC 33:III.2121.C may be modified as follows:

       1.  Alternate Standards for Valves and Pumps subject to LAC 33:III.2121.C.1.b - Skip Period Leak Detection and Repair:

           a.  An owner or operator may elect to comply with one  of the alternative work practices specified in LAC 33:III.2121.D.1.b and c. However, the administrative authority must be notified before implementing one of the alternative work practices.

           b.  After two consecutive quarterly leak detection periods with the percent of components leaking equal to or less than 2.0, an owner or operator may begin to skip one of the quarterly leak detection periods for the valves in gas/vapor and liquid service and pumps in light liquid service.

           c.  After five consecutive quarterly leak detection periods with the percent of components leaking equal to or less than 2.0, an owner or operator may begin to skip three of the quarterly leak detection periods for the valves in gas/vapor and liquid service and pumps in light liquid service.

           d.  If the percent of components leaking is greater than 2.0, the owner or operator shall comply with the requirements as described in LAC 33:III.2121.C but subsequently can again elect to use this Subsection.

           e.  The percent of components leaking shall be determined by dividing the sum of components found leaking during current monitoring and components for which repair has been delayed by the total number of components subject to the requirements of LAC 33:III.2121.C.

           f. An owner or operator must keep a record of the percent of valves and pumps found leaking during each leak detection period.

      2. Alternative Standards for Valves and Pumps - Increased Monitoring Frequency.  If there is an excessive number of leaks (greater than the good performance level), then an increase in the frequency of monitoring may be required.

  E. Recordkeeping

      1. When a leak that cannot be repaired on-line and in-place, as described in LAC 33:III.2121.B is located, a weatherproof and readily visible tag bearing an identification number and the date the leak is located shall be affixed to the leaking component.  After the leak is repaired the tag is dated and removed.

      2. A survey log shall be maintained by the operator which shall include the following:

            a. The name of the process unit where the leaking component is located.

            b. The name of the leaking component.

            c. The stream identification at the leak.

            d. The identification number from the tag required by LAC 33:III.2121.E.1

            e. The date the leak was located.

            f. The date maintenance was performed.

            g. The date the component was rechecked after maintenance, as well as the instrument reading upon check (For natural gas processing plants the soap bubble test commonly performed in the industry is satisfactory).

            h. a record of leak detection device calibration.

            i. a listing of leaks not repaired until turnaround.

            j. a list of total number of items checked versus the
total found leaking.

       3. The operator shall retain the survey log for two years after the latter date specified in LAC 33:.III.2121.E.2 and make said log available to the administrative authority upon request.

  F. Reporting Requirements. The operator of the affected facility shall, after each quarterly monitoring has been performed, submit a report listing all leaks that were located but not repaired within the 15 day limit along with a demonstration of achieving "good performance level."  These reports are due by the last day of January, April, July, and October.  Such reports shall include the following:

          1. the name of the unit where the leaking component is located, the date of last unit shutdown.

          2. the name of the leaking component.

          3. the stream identification at the leak.

          4. the date the leak was located.

          5. the date maintenance was attempted.

          6. the date the leak will be repaired.

          7. the reason repairs failed or were postponed.

          8. the list of items awaiting turnaround for repair.

          9. the number of items checked versus the number found leaking.

         10. the operator shall include in this report a signed statement attesting to the fact that all other monitoring has been performed as required by the regulations.

 G. Definitions.  Terms used in this Section are defined in LAC 33:III.111 of these regulations with the exception of those terms specifically defined below as follows:

      Heavy liquid service - equipment that is not in gas/vapor service or is not in light liquid service.

      Inaccessible valve - a valve that cannot be monitored without elevating the monitoring personnel more than two meters above a support service.
      Light liquid - a fluid with a vapor pressure greater than 0.3 kPa at 20 degrees C.

      Light liquid service - equipment in liquid service contacting a fluid greater than 10 percent by weight light liquid.

      Liquid service - equipment which processes, transfers or contains a VOC or mixture of VOC in the liquid phase.


   AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.

   HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Nuclear Energy, Air Quality Division, LR 13:741 (December 1987), amended LR 16:959 (November 1990), amended by the Office of Air Quality and Radiation Protection, Air Quality Division, LR 17:654 (July 1991).

********************** end section 2121 ******************86t**
This SIP Citation Was Last Modified on: 06/20/98


Section 2122.  Fugitive Emission Control for Ozone Nonattainment Areas. LAc71
Approved by EPA 10/22/96 (61 FR 54742) at 52.970(c)(71) effective 12/23/96.

  A.  Applicability

    1.  This regulation is applicable to each process unit at petroleum refineries, natural gas processing plants, the synthetic organic chemical manufacturing industry (SOCMI), the methyl tertiary butyl ether (MTBE) manufacturing industry, and the polymer manufacturing industry that contains any of the following components that are intended to operate in VOC service 300 hours or more during the calendar year:  pumps, compressors, pressure relief devices, open-ended valves or lines, process drains, valves, agitators, and connectors.

    2.  Where the provisions of this Section are effective, process units to which this Section applies that are also subject to the provisions of LAC 33:III.2121 will not be required to comply with the provisions of LAC 33:III.2121.  Process units that are currently being monitored under LAC 33:III.2121 for fugitives shall be subject to the requirements of that rule until January 1, 1996.

    3.  Reserved.

    4.  The requirements of this Section shall be effective starting January 1, 1996.

    5.  This Section is applicable to sources in areas classified nonattainment for ozone and designated as moderate, severe, serious, or extreme as defined in the Clean Air Act Amendments of 1990 (Public Law 101-549).

    6.  Applicable facilities as defined in Subsection A.1 of this Section which are subject to New Source Performance Standards, LAC 33:III.3730 to 3749 (Subchapter VV), 4780 to 4783 (Subchapter GGG), 4820 to 4826 (Subchapter KKK), or 5171 (Subchapter V) may become exempt from this Section by:
      a.  submitting a written notice to the administrative authority* informing them of the facility's request to become exempt from LAC 33:III.2122 and how LAC 33:III.3730 to 3749 (Subchapter VV), 4780 to 4783 (Subchapter GGG), 4820 to 4826 (Subchapter KKK), or 5171 (Subchapter V) will be administered to obtain that exemption;
      b.  applying LAC 33:III.3730 to 3749 (Subchapter VV), 4780 to 4783 (Subchapter GGG), 4820 to 4826 (Subchapter KKK), or 5171 (Subchapter V) to leak limitations specified in Subsection C.1 of this Section rather than 10,000 ppm as specified in LAC 33:III.3730 to 3749 (Subchapter VV), 4780 to 4783 (Subchapter GGG), 4820 to 4826 (Subchapter KKK), or 5171 (Subchapter V);
      c.  including connectors as leak sources monitored and repaired using the restrictions in LAC 33:III.3730 to 3749 (Subchapter VV), 4780 to 4783 (Subchapter GGG), 4820 to 4826 (Subchapter KKK), or 5171 (Subchapter V) which apply to valves, and
      d.  increasing monitoring frequency only when the leaking sources monitored and repaired using the restrictions in LAC 33:III.3730 to 3749 (Subchapter VV), 4780 to 4783 (Subchapter GGG), 4820 to 4826 (Subchapter KKK), or 5171 (Subchapter V) which apply to valves equal or exceed two percent of the valves monitored at or above 10,000 ppm.

  B.  Definitions.  Terms in this Section are used as defined in LAC 33:III.111 with the exception of those terms specifically defined below.

    Connector -- flanged, screwed, or other joined fittings used to connect two pipe lines or a pipe line and a piece of equipment. Welded connections are not connectors.

    Good Performance Level -- an operating level reached when no more than 2.0 percent of a component in VOC service in a process unit are leaking at the leak rate definition or greater as determined by LAC 33:III.6077 (Reference Method 21, "Determination of Volatile Organic Compound Leaks").

    Heavy Liquid Service -- equipment that is not in VOC gas/vapor service or is not in VOC light liquid service.

    Inaccessible Valve/Connector -- a valve/connector that cannot be monitored without elevating the monitoring personnel more than two meters above a support surface.

    In Vacuum Service -- equipment operating at an internal pressure that is at least 20 inches of water (38 mm of Hg) below ambient pressure.

    Light Liquid -- a fluid with a vapor pressure greater than 0.3 kPa (0.0435 psia) at 20 degrees C (68 degrees F) or a fluid for which the weight percent evaporation at 150 degrees C exceeds 10 percent as determined by ASTM D86.

    Light Liquid Service -- equipment in liquid service contacting a fluid greater than 10 percent by weight light liquid.

    Liquid Service -- equipment which processes, transfers, or contains a VOC or mixture of VOC in the liquid phase.

    Process Unit -- a process unit that can operate independently if supplied with sufficient feed or raw materials and sufficient storage facilities for the product.

    Process Unit Shutdown -- a work practice or operational procedure that stops production from a process unit or part of a process unit during which it is technically feasible to clear process material from a process unit or part of a process unit  consistent with safety constraints and during which repairs can be effected.  An unscheduled work practice or operational procedure that stops production from a process unit or part of a process unit for less than 24 hours is not a process unit shutdown.  An unscheduled work practice or operational procedure that would stop production from a process unit or part of a process unit for a shorter period of time than would be required to clear the process unit or part of the process unit of materials and start-up the unit, and would result in greater emissions than delay of repair of leaking components until the next scheduled process unit shutdown, is not a process unit shutdown.  The use of spare equipment and technically feasible bypassing of equipment without stopping production are not process unit shutdowns.

    Unrepairable Component -- unrepairable components are those designated as requiring a process unit shutdown to repair where more emissions would be created by an immediate facility shutdown than allowing the component to leak until the next scheduled shutdown, and the component is listed on a shutdown list for repairs.

  C.  Fugitive Emission Control Requirements
    1.  Leak Limitations
      a.  No component in petroleum refineries, SOCMI, MTBE, and polymer manufacturing industry shall be allowed to leak volatile organic compounds exceeding an instrument reading of 1,000 ppmv or greater for valves, connectors, pressure relief devices, process drains, and open-ended valves and lines; 5,000 ppmv for pumps and compressors; or 10,000 ppmv for agitators as outlined in Subsection D of this Section, when tested by LAC 33:III.6077.
       b.  No component in natural gas processing plants shall be allowed to leak volatile organic compounds exceeding an instrument reading off of 2,500 ppmv for valves, connectors, pressure relief devices, process drains, and open-ended valves and lines; 5,000 ppmv for pumps and compressors; or 10,000 ppmv for agitators as outlined in Subsection D of this Section, when tested by LAC 33:III.6077.

      c.  Any regulated component observed leaking by sight, sound, or smell must be repaired according to Subsection C.3 of this Section, regardless of the leak's concentration.  This includes flange and connection leaks found per Subsection D.3.b of this Section, pump and compressor seal leaks found during the weekly visual inspections, and any other regulated component found leaking.
    2.  No valve, except safety pressure relief valves, shall be located at the end of a pipe or line containing volatile organic compounds unless the end of such line is sealed with a second valve, a blind flange, a plug, or a cap.  Such sealing devices may be removed only when the line is in use, for example, when a sample is being taken.  When the line has been used and is subsequently resealed, the upstream valve shall be closed first, followed by the sealing device.
     3.  The operator shall make every reasonable effort to repair a leaking component, as described in this Subsection, within 15 days. If the component cannot be isolated or bypassed so as to significantly reduce or eliminate leakage, or if the repair of a component would require a unit shutdown, and if the shutdown would create more emissions than the repair would eliminate, the repair may be delayed to the next scheduled shutdown.  The delay of repair shall not be any later than the next scheduled process unit shutdown.  An early unit shutdown may be ordered if the total percentage of leaking and unrepairable components are excessive.     4.  Percent of leaking components at a process unit shall be determined for a test period as follows:

              Clv
  % Clvp =  -------  * 100%                          Eq. 1
              Ctv

  where:
    % Clvp = percent of a leaking components, where the component is the classification of valves or pumps.
    Clv = number of valves or pumps found leaking during the monitoring period.
    Ctv = total number of valves or pumps monitored during the period.

    5.  Total percent of leaking and unrepairable components shall be determined as follows:

                 Ctlv
  % Ctlvp =  ------------ * 100%                     Eq. 2
             Cttv + Ctuvp
  where:
    Percent Ctlvp = total percent of leaking and unrepairable valves or pumps.
    Ctlv = number of valves or pumps found leaking or defined as unrepairable.
    Cttv = total number of valves or pumps tested during the period.
    Ctuvp   = total number of valves or pumps which were defined as unrepairable.

  D.  Monitoring Requirements.  The monitoring of the affected components shall be performed by the following schedule using the method described in Subsection C of this Section or one of the alternate monitoring programs in Subsection E of this Section.

    1.  Petroleum Refineries, SOCMI, MTBE, and Polymer Manufacturing Industry
      a.  Monitor with a leak detection device one time per year (annually) the following items:
        i.  process drains; and
        ii.  open-ended valves and lines.
      b.  Monitor with a leak detection device four times per year (quarterly) the following items:
        i.  compressor seals;
        ii.  pressure relief valves in gas service;
        iii.  valves in light liquid service;
        iv.  pumps in light liquid service; and
        v.  valves in gas service.
      c.  Monitor pump seals visually 52 times a year (weekly).
      d.  Inspect weekly, by visual, audible, and olfactory means, all flanges and measure the emissions with a hydrogen gas analyzer from any component within five days after a potential leak is detected by sight, sound, or smell.
      e.  Records of the visual, audible, and olfactory inspections of connectors are not required unless a leak is detected.

    2.  Natural Gas Processing Plants
      a.  Monitor pump seals and compressor seals visually 52 times a year (weekly).
      b.  Monitor with a leak detection device four times a year (quarterly) the following items:
        i.  pumps, pump and compressor seals;
        ii.  valves; and
        iii.  pressure relief valves in gas service.

    3.  Facilities listed in Subsection D.1 and 2 of this Section
      a.  Monitor with a leak detection device any pressure relief valve within 24 hours after it has vented to the atmosphere.  (For natural gas processing plants an immediate visual evaluation will be made.)
      b.  Monitor immediately with a leak detection device any component that appears to be leaking on the basis of sight, smell, or sound.  In lieu of monitoring, the operator may elect to implement actions as specified in Subsection C of this Section.
      c.  Inaccessible valves shall be monitored on an annual basis at a minimum,
      d.  Unsafe-to-monitor valves and connectors shall be monitored when conditions would allow these valves and connectors to be monitored safely (e.g., during shutdown).

    4.  Exemptions.  Monitoring is not required on the following:
      a.  components subject to Subsection D.1 of this Section (petroleum refineries, SOCMI, MTBE, and polymer manufacturing industry) which contact a process fluid that contains less than 10 percent VOC by volume or components subject to Subsection D.2 of this Section (natural gas processing plants) which contact a process fluid that contains less than 1.0 percent VOC by weight;
      b.  components in the petroleum refineries, SOCMI, MTBE, and polymer manufacturing industry that contact only a process liquid containing a VOC having a true vapor pressure equal to or less than 0.3 kPa (0.0435 psia) at 20 degrees C (68 degrees F).
      c.  pressure relief valves in liquid service at SOCMI and polymer manufacturing industry, except after venting;
      d.  pressure relief devices, pump seals or packing, and compressor seals or packing where leaks are vented to either a flare header or vapor recovery device;
      e.  equipment in vacuum service;
      f.  natural gas processing plants with less than 40 million cubic feet per day (mmcfd) capacity that do not fractionate natural gas liquids;
      g.  components contacting only organic compounds exempted under LAC 33:III.2117 or mixtures of same with water;
      h.  pumps and compressors with double mechanical seal;
      i.  research and development pilot facilities and small facilities with less than 100 valves in gas or liquid service;
      j.  insulated connectors;
      k.  components that have been placed on a shutdown list for repairs are exempt from further monitoring until a repair has been attempted.

    5.  Alternate Monitoring Program.  Any facility that already has in place a fugitive emission monitoring program which controls to a higher degree than required under this Section shall be exempted from this Section upon submittal of a description of the program to the administrative authority* and approval thereof.

  E.  Alternate Control Techniques.  The monitoring schedule in Subsection D of this Section may be modified as follows:

    1.  Alternate Standards for Valves subject to Subsection D.1.b or D.2.b of this Section - Skip Period Leak Detection and Repair.
      a.  An owner or operator may elect to comply with one of the alternative work practices specified in Subsection E.1.b, c, g, or 2 of this Section.  However, the administrative authority* must be notified in writing before implementing one of the alternative work practices.
      b.  After two consecutive quarterly leak detection periods with the percent of leaking valves (Eq. 1) equal to or less than 2.0, an owner or operator may begin to skip one of the quarterly leak detection periods for the valves in gas/vapor and light liquid service.
      c.  After five consecutive quarterly leak detection periods with the percent of leaking valves (Eq. 1) equal to or less than 2.0, an owner or operator may begin to skip three of the quarterly leak detection periods for the valves in gas/vapor and light liquid service.
      d.  If the percent of leaking valves (Eq. 1) is greater than 2.0, or the total percent of leaking and unrepairable valves (Eq. 2) is greater than 4.0, the owner or operator shall comply with the requirements as described in Subsection D of this Section but subsequently can again elect to use this Subsection when the requirements are met.
      e.  The percent of leaking valves (Eq. 1) shall be determined by dividing the sum of components found leaking during the current monitoring period by the total number of valves which were tested and multiplying the results by 100 percent.
      f.  An owner or operator must keep a record of the percent of valves found leaking during each leak detection period and the total percentage of leaking and unrepairable valves.
      g.  Existing equipment that has been monitored under LAC 33:III.2121 for fugitives at the leak definition of 10,000 ppmv can initially elect to use this alternate standard if the unit has data documented by January 1, 1996, with the department that indicates the percent of leaking valves (Eq. 1) is less than or equal to 2.0 percent leak rate at 10,000 ppmv for the required time period.

    2.  Alternative Standards for Valves - Increased Monitoring Frequency.  If the percent of leaking valves (Eq. 1) in a test period is greater than 2.0, or the total percent of leaking and unrepairable valves (Eq. 2) is greater than 4.0, then an increase in the frequency of monitoring may be required by the administrative authority*.

    3.  Alternate Standard for Batch Processes.  As an alternate to complying with the requirements in Subsection D of this Section an owner or operator of a batch process in VOC service may elect to comply with one of the following alternative work practices.  The batch product-process equipment shall be tested with a gas using the procedures specified in Subsection E.3.a of this Section or with a liquid as specified in Subsection E.3.b of this Section.
      a.  The following procedures shall be used to pressure test batch product-process equipment using a gas (e.g., air or nitrogen) to demonstrate compliance.
        i.  The batch product-process equipment train shall be pressurized with a gas to the operating pressure of the equipment. The equipment shall not be tested at a pressure greater than the pressure setting of the lowest relief valve setting.
        ii.  Once the test pressure is obtained, the gas source shall be shut off.
        iii.  The test shall continue for not less than 15 minutes unless it can be determined in a shorter period of time that the allowable rate of pressure drop was exceeded.  The pressure in the batch product-process equipment shall be measured after the gas source is shut off and at the end of the test period.  The rate of change in pressure in the batch product-process equipment shall be calculated using the following equation:

      P     (Pf - Pi)
      -   = ---------                                Eq. 5
      t     (tf - ti)

  where:
    P/t = change in pressure, psia/hr.
    Pf = final pressure, psia.
    Pi = initial pressure, psia.
    tf - ti = elapsed time, hours.

        iv.  The pressure shall be measured using a pressure measurement device (gauge, manometer, or equivalent) which has a precision of ±2.5 millimeters (±0.05 psig) of mercury in the range of test pressure and is capable of measuring pressures up to the relief set pressure of the pressure relief device.
        v.  A leak is detected if the rate of change in pressure is greater than 6.9 kPa (1 psig) in one hour or if there is visible, audible, or olfactory evidence of fluid loss.
      b.  The following procedures shall be used to pressure test batch product-process equipment using a liquid to demonstrate compliance.
        i.  The batch product-process equipment train, or section of the train, shall be filled with the test liquid (e.g., water, alcohol). Once the equipment is filled, the liquid source shall be shut off.
        ii.  The test shall be conducted for a period of at least 60 minutes, unless it can be determined in a shorter period of time that the test is a failure.
        iii.  Each seal in the equipment being tested shall be inspected for indications of liquid dripping or other indications of fluid loss.  If there are any indications of liquids dripping or of fluid loss, a leak is detected.
        iv.  If a leak is detected, it shall be repaired and the batch product-process equipment shall be retested before VOCs are fed to the equipment.
        v.  If the batch product-process equipment fails the retest or the second of two consecutive pressure tests, it shall be repaired as soon as practicable, but not later than 30 calendar days after the equipment is placed in VOC service.

  F.  Recordkeeping

    1.  When a component which has a leak that cannot be repaired, as described in Subsection C of this Section, is located, a weatherproof and readily visible tag bearing an identification number and the date the leak is located shall be affixed to the leaking component.  After the leak has been repaired the tag identifying the component as a leaking component may be removed.

    2.  A survey log shall be maintained by the operator and shall include the following:
      a.  the name of the process unit where the leaking component is located;
      b.  the name of the leaking component;
      c.  the stream identification at the leak;
      d.  the identification number from the tag required by Subsection F.1 of this Section;
      e.  the date the leak was located;
      f.  the date maintenance was performed;
      g.  the date(s) the component was rechecked after maintenance, as well as the instrument reading(s) upon recheck (For natural gas processing plants the soap bubble test commonly performed in the industry is satisfactory.);
      h.  a record of leak detection device calibration;
      i.  a list of leaks not repaired until turnaround;
      j.  a list of total number of items checked versus the total found leaking.

    3.  The operator shall retain the survey log for two years after the latter date specified in Subsection F.2 of this Section and make said log available to the administrative authority* upon request.

  G.  Reporting Requirements.  The operator of the affected facility shall, after each quarterly monitoring has been performed, submit a report listing all leaks that were located but not repaired within the 15-day limit along with a demonstration of achieving good performance level.  These reports are due by the last day of January, April, July, and October.  For units complying with the alternate control techniques a report shall be submitted by the last day of the month following the quarter that monitoring was performed.  Such reports shall include the following:
    1.  the name of the unit where the leaking component is located and the date of last unit shutdown;
    2.  the name of the leaking component;
    3.  the stream identification at the leak;
    4.  the date the leak was located;
    5.  the date maintenance was attempted;
    6.  the date the leak will be repaired if the component is awaiting a shutdown;
    7.  the reason repairs failed or were postponed;
    8.  the list of items awaiting turnaround for repair;
    9.  the number of items checked versus the number found leaking;
    10.  the percent of components leaking for the test period;
    11.  the total percent of leakers;
    12.  an explanation of any random sampling method used to ensure periodic testing of all connectors; and
    13.  a signed statement attesting to the fact that all other monitoring has been performed as required by the regulations.

  AUTHORITY NOTE:  Promulgated in accordance with R.S. 30:2054.
  HISTORICAL NOTE:  Promulgated by the Department of Environmental Quality, Office of Air Quality and Radiation Protection, Air Quality Division, LR 20:1102 (October 1994), repromulgated LR 20:1269 (November 1994).

****************** end section 2122 ***********************86t***
This SIP Citation Was Last Modified on: 07/03/98
*********** end chapter 21 subchapter a *******************s79***