You may need a PDF reader to view some of the files on this page. See EPA’s About PDF page to learn more.Substitutes are reviewed on the basis of environmental and health risks, including factors such as ozone depletion potential, global warming potential, toxicity, flammability, and exposure potential. Lists of acceptableacceptableThis designation means that a substitute may be used, without restriction, to replace the relevant ODS within the end-use specified. For example, HCFC-22 is an acceptable substitute for R-502 in industrial process refrigeration. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. and unacceptable
UnacceptableThis designation means that it is illegal to use a product as a substitute for an ODS in a specific end-use. For example, HCFC-141b is an unacceptable substitute for CFC-11 in building chillers. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. substitutes are updated several times each year. The list of substitutes is shown below.
Note: SNAP-related information published in the Federal Register takes precedence over all information on this page.
Substitute | Trade Name(s) | Retrofit/New | ODP![]() |
GWP![]() |
ASHRAE![]() Designation (Safety Classification) |
SNAP Listing Date | Listing Status |
---|---|---|---|---|---|---|---|
C6 Perfluoroketone | NovecTM 649 | R/N | 0 | 0.6 - 1.8 | A1 | September 30, 2009; June 16, 2010 |
Acceptable |
C7 Fluoroketone | NovecTM 774 | R/N | 0 | 1 | A1 | August 10, 2012 | Acceptable |
Galden Fluids | R | 0 | N/A | A1 | February 24, 1998 | Acceptable | |
HFC-236fa | R/N | 0 | 9,810 | A1 | June 8, 1999 | Acceptable with Use Conditions: When manufactured using any process that does not convert perfluoroisobutylene (PFIB) directly to HFC-236fa in a single step. | |
HFC-245fa | Genetron® 245fa | R/N | 0 | 1,030 | A1 | March 29, 2006; June 16, 2010 |
Acceptable |
HFC-4310mee | R/N | 0 | 1,640 | A1 | June 19, 2000 | Acceptable | |
HFE-347mcc3 (heptafluoropropyl methyl ether) | Novec™ 7000 Engineered Fluid (HFE-7000) | R/N | 0 | 575 | A1 | March 22, 2002; June 16, 2010 |
Acceptable |
HFE-449s1 (methoxynonafluorobutane, iso and normal) | Novec™ 7100 Engineered Fluid (HFE-7100) | R/N | 0 | 297 | A1 | June 8, 1999; June 16, 2010 |
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
HFE-569sf2 (ethoxynonafluorobutane, iso and normal) | Novec™ 7200 Engineered Fluid (HFE-7200) | R/N | 0 | 59 | N/A | December 18, 2000; June 16, 2010 |
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
HFE-64-13m(m)yy(s)c3 (1,1,1,2,2,3,4,5,5,5-decafluoro-3-methoxy-4-(trifluoromethyl)pentane) | Novec™ 7300 Engineered Fluid (HFE-7300) | R/N | 0 | 310 | A1 | July 21, 2017 | Acceptable |
HFO-1234ze | Solstice® 1234ze | R/N | 0 | 6 | A2L | June 16, 2010 | Acceptable |
HFO-1336mzz(Z) ((Z)-1,1,1,4,4,4-hexafluorobut-2-ene) | Opteon® MZ | N | 0 | 9 | A1 | May 23, 2016 | Acceptable |
Methoxytridecafluoroheptene isomers | MPHE; SineraTM | R/N | 0 | 2.5 | A1 | July 16, 2015 | Acceptable |
Mineral Oil | R/N | 0 | 0 | N/A | July 28, 1995 | Acceptable | |
PFCs (C3F8, C4F10, C5F12, C5F11NO, C6F14, C6F13NO, C7F16, C7F15NO, C8F18, C8F17NO, C9F21N) | R/N | 0 | N/A | N/A | N/A | Acceptable with Use Conditions: PFCs are only allowed in new systems where a study has demonstrated that no other alternatives are technically feasible due to safety or performance requirements; this study must be kept available for review. | |
R-125/R-290/R-134a/R-600a (55.0/1.0/42.5/1.5) | ICOR AT-22 | R/N | 0 | 2,530 | A1 | March 29, 2006 | Acceptable |
R-170 (Ethane) | N | 0 | 5.5 | A3 | April 10, 2015 | Acceptable with Use Conditions: See rule for detailed conditions. | |
R-404A | SUVA HP-62 | R/N | 0 | 3,920 | A1 | December 20, 2002 | Acceptable |
R-407C | Suva 407C, Klea 407C | R/N | 0 | 1,770 | A1 | December 20, 2002; August 21, 2003 |
Acceptable |
R-410A | AZ-20, Suva 9100, Puron | N | 0 | 2,090 | A1 | December 20, 2002 | Acceptable |
R-417A | ISCEON 59, NU-22 | R/N | 0 | 2,350 | A1 | December 6, 1999; June 16, 2010 |
Acceptable |
R-422B | ICOR XAC1, NU-22B | R/N | 0 | 2,530 | A1 | March 29, 2006 | Acceptable |
R-422C | ICOR XLT1 | R/N | 0 | 3,390 | A1 | March 29, 2006 | Acceptable |
R-422D | ISCEON MO29 | R/N | 0 | 2,730 | A1 | September 28, 2006 | Acceptable |
R-437A | KDD6, ISCEON MO49 Plus | R/N | 0 | 1,810 | A1 | January 2, 2009 | Acceptable |
R-438A | KDD5, ISCEON MO99 | R/N | 0 | 2,270 | A1 | October 4, 2007; June 16, 2010 |
Acceptable |
R-507, R-507A | AZ-50 | R/N | 0 | 3,990 | A1 | December 20, 2002 | Acceptable |
R-744 (Carbon Dioxide, CO2) | R/N | 0 | 1 | A1 | January 13, 1995; June 16, 2010 |
Acceptable | |
Trans-1-chloro-3,3,3-trifluoroprop-1-ene | Solstice® 1233zd(E), Solstice N12 Refrigerant | N | 0.00024 - 0.00034 | 4.7 - 7 | A1 | October 21, 2014 | Acceptable |
Volatile Methyl Siloxanes | R/N | 0 | <20 | N/A | July 28, 1995; June 16, 2010 |
Acceptable | |
Water | R/N | 0 | N/A | A1 | July 28, 1995; June 16, 2010 |
Acceptable |
Back to the Refrigeration and Air Conditioning sector page.