Substitutes in Phenolic Insulation Board and Bunstock
You may need a PDF reader to view some of the files on this page. See EPA’s About PDF page to learn more.Substitutes are reviewed on the basis of environmental and health risks, including factors such as ozone depletion potential, global warming potential, toxicity, flammability, and exposure potential. Lists of acceptableacceptableThis designation means that a substitute may be used, without restriction, to replace the relevant ODS within the end-use specified. For example, HCFC-22 is an acceptable substitute for R-502 in industrial process refrigeration. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. and Unacceptable
UnacceptableThis designation means that it is illegal to use a product as a substitute for an ODS in a specific end-use. For example, HCFC-141b is an unacceptable substitute for CFC-11 in building chillers. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. substitutes are updated several times each year. The list of substitutes is shown below.
Note: SNAP-related information published in the Federal Register takes precedence over all information on this page.
Substitute | Trade Name(s) | ODP![]() |
GWP![]() |
Flammable | SNAP Listing Date | Listing Status[1] | Further Information |
---|---|---|---|---|---|---|---|
2-Chloropropane | 0 | 5 or less | yes | March 18, 1994; June 16, 2010 |
Acceptable | ||
Blends of HFC-245fa and HCFC-22 | >0 | N/A | no | August 21, 2003; July 20, 2015 |
Unacceptable as of September 18, 2015. | ||
Carbon Dioxide | 0 | 1 | no | March 18, 1994; June 8, 1999 |
Acceptable | ||
EcomateTM | EcomateTM | 0 | 5 or less | yes | September 28, 2006 | Acceptable | |
Electroset Technology | 0 | N/A | N/A | August 26, 1994; June 16, 2010 |
Acceptable | ||
Exxsol Blowing Agents | 0 | 5 or less | yes | December 6, 1999; June 16, 2010 |
Acceptable | ||
HCFC-124 | 0.022 | 609 | no | July 22, 2002 | Unacceptable | Alternatives exist with lower or zero ODP. | |
HCFC-141b | 0.12 | 725 | no | September 30, 2004; July 20, 2015 |
Unacceptable | Alternatives exist with lower or zero ODP. | |
HCFC-22, HCFC-142b or blends thereof | >0 | N/A | no | July 22, 2002; July 20, 2015 |
Unacceptable | Alternatives exist with lower or zero ODP. | |
HFC-134a | 0 | 1,430 | no | March 18, 1994; June 8, 1999; July 20, 2015; December 1, 2016 |
Unacceptable, except where allowed under narrowed use limits for military or space- and aeronautics-related applications, as of January 1, 2017. [2] Unacceptable for military applications as of January 1, 2022 and for space- and aeronautics-related applications as of January 1, 2025. [2] |
||
HFC-143a | 0 | 4,470 | yes | July 20, 2015; December 1, 2016 |
Unacceptable, except where allowed under narrowed use limits for military or space- and aeronautics-related applications, as of January 1, 2017. [2] Unacceptable for military applications as of January 1, 2022 and for space- and aeronautics-related applications as of January 1, 2025. [2] |
||
HFC-152a | 0 | 124 | yes | June 8, 1999 | Acceptable | ||
HFC-245fa | 0 | 1,030 | no | December 6, 1999; August 21, 2003; July 20, 2015; December 1, 2016 |
Unacceptable, except where allowed under narrowed use limits for military or space- and aeronautics-related applications, as of January 1, 2017. [2] Unacceptable for military applications as of January 1, 2022 and for space- and aeronautics-related applications as of January 1, 2025. [2] |
||
HFC-365mfc | 0 | 794 | yes | September 30, 2009; June 16, 2010; July 20, 2015; December 1, 2016 |
Unacceptable, except where allowed under narrowed use limits for military or space- and aeronautics-related applications, as of January 1, 2017. [2] Unacceptable for military applications as of January 1, 2022 and for space- and aeronautics-related applications as of January 1, 2025. [2] |
||
HFO-1234ze | 0 | 6 | no | June 16, 2010 | Acceptable | ||
HFO–1336mzz(Z) ((Z)-1,1,1,4,4,4-hexafluorobut-2-ene) | Formacel® 1100, FEA-1100 | 0 | 9 | no | October 21, 2014 | Acceptable | |
Saturated Light Hydrocarbons (C3-C6) | 0 | 3 - 10 | yes | March 18, 1994; April 11, 2000; June 16, 2010 |
Acceptable | ||
Water | 0 | N/A | no | June 8, 1999 | Acceptable |
1 Use of closed cell foam products and products that contain closed cell foam manufactured with an Unacceptable foam blowing agent prohibited on or before the later of: 1) December 1, 2017, or 2) the date when the foam blowing agent is Unacceptable.
2 As per EPA’s April 27, 2018 guidance (83 FR 18431), based on the court’s partial vacatur, in the near term EPA will not apply these HFC listings in the 2015 Rule, pending a rulemaking.