Substitutes in Rigid Polyurethane: Spray
You may need a PDF reader to view some of the files on this page. See EPA’s About PDF page to learn more.Substitutes are reviewed on the basis of environmental and health risks, including factors such as ozone depletion potential, global warming potential, toxicity, flammability, and exposure potential. Lists of acceptableacceptableThis designation means that a substitute may be used, without restriction, to replace the relevant ODS within the end-use specified. For example, HCFC-22 is an acceptable substitute for R-502 in industrial process refrigeration. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. and Unacceptable
UnacceptableThis designation means that it is illegal to use a product as a substitute for an ODS in a specific end-use. For example, HCFC-141b is an unacceptable substitute for CFC-11 in building chillers. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. substitutes are updated several times each year. The list of substitutes is shown below.
Note: SNAP-related information published in the Federal Register takes precedence over all information on this page.
Substitute | Trade Name(s) | ODP![]() |
GWP![]() |
Flammable | SNAP Listing Date | Listing Status | Further Information |
---|---|---|---|---|---|---|---|
Blends of HFC-365mfc and HFC-245fa, containing at least 5% HFC-245fa | 0 | 865 - 960 | no | September 30, 2009; June 16, 2010; December 1, 2016 |
High-pressure two-component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2020; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2020; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [3] Low-pressure two component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2021; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2021; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [4] One-component foam sealants: Unacceptable, as of January 1, 2020. [5] |
||
Carbon Dioxide | 0 | 1 | no | March 18, 1994; June 8, 1999 |
Acceptable | ||
Commercial blends of HFC-365mfc and HFC-227ea containing 7% to 13% HFC-227ea and the remainder HFC-365mfc | Solkane® 365/227 | 0 | N/A | no | May 17, 2013; December 1, 2016 |
High-pressure two-component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2020; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2020; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [3] Low-pressure two component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2021; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2021; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [4] One-component foam sealants: Unacceptable, as of January 1, 2020. [5] |
|
Methyl Formate | Ecomate™ | 0 | 5 or less | yes | October 1, 2004 | Acceptable | |
Methylal | Novicell™ | 0 | <1 | yes | December 11, 2020 | Acceptable | |
Electroset Technology | 0 | N/A | N/A | August 26, 1994; June 16, 2010 |
Acceptable | ||
Exxsol Blowing Agents | Exxsol Blowing Agents | 0 | 5 or less | yes | December 6, 1999; June 16, 2010 |
Acceptable | |
Formacel® TI | Formacel® TI | 0 | 1,330 - 1,500 | no | September 30, 2009; December 1, 2016 |
High-pressure two-component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2020; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2020; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [3] Low-pressure two component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2021; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2021; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [4] One-component foam sealants: Unacceptable, as of January 1, 2020. [5] |
|
Formic Acid | 0 | 5 or less | yes [2] | September 5, 1996 | Acceptable | ||
HCFC-123 | 0.02 | 77 | no | March 18, 1994 | Acceptable | ||
HCFC-124 | 0.022 | 609 | no | July 22, 2002 | Unacceptable | Alternatives exist with lower or zero ODP. | |
HCFC-141b | 0.12 | 725 | no | September 30, 2004; July 20, 2015 |
Unacceptable | Alternatives exist with lower or zero ODP. | |
HCFC-141b/HCFC-123 Blends | >0 | N/A | no | July 20, 2015 | Unacceptable as of September 18, 2015. | ||
HCFC-22, HCFC-142b or blends thereof | >0 | N/A | no | July 22, 2002; July 20, 2015 |
Unacceptable | Alternatives exist with lower or zero ODP. | |
HFC-134a | 0 | 1,430 | no | March 18, 1994; June 8, 1999; December 1, 2016 |
High-pressure two-component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2020; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2020; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [3] Low-pressure two component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2021; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2021; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [4] One-component foam sealants: Unacceptable, as of January 1, 2020. [5] |
||
HFC-152a | 0 | 124 | yes | March 18, 1994; June 8, 1999 |
Acceptable | ||
HFC-245fa | 0 | 1,030 | no | December 6, 1999; December 1, 2016 |
High-pressure two-component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2020; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2020; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [3] Low-pressure two component spray foam: Unacceptable for all uses, except military or space- and aeronautics-related applications, as of January 1, 2021; Acceptable, subject to narrowed use limits, for military or space- and aeronautics-related applications, as of January 1, 2021; Unacceptable for military or space- and aeronautics-related applications as of January 1, 2025. [4] One-component foam sealants: Unacceptable, as of January 1, 2020. [5] |
||
HFO-1234ze | 0 | 6 | no | September 30, 2009 | Acceptable | ||
HFO-1336mzz(E) | Opteon™ 1150 | 0 | 16 | no | December 11, 2020 | Acceptable | |
HFO–1336mzz(Z) ((Z)-1,1,1,4,4,4-hexafluorobut-2-ene) | Formacel® 1100, FEA-1100 | 0 | 9 | no | July 16, 2015 | Acceptable: High-pressure, two part uses only. | |
Trans-1-chloro-3,3,3-trifluoroprop-1-ene | Solstice® 1233zd(E) | 0.00024 - 0.00034 | 4.7 - 7 | no | August 10, 2012 | Acceptable | |
TranscendTM Technologies | Transcend™ Technologies | 0 | 5 or less | yes[1] | March 29, 2006 | Acceptable as an additive to SNAP-approved blowing agents in blends making up to 5% by weight of the total foam formulation. For spray foam, TranscendTM Technologies may only be used with other blowing agents that are SNAP-approved specifically for spray foam. | |
Water | 0 | N/A | no | June 8, 1999 | Acceptable |
1 When blended with fire retardant and/or other SNAP-approved alternatives, the flammability of TranscendTM Technologies can be reduced to make a formulation that is either combustible or non-flammable (contact the manufacturer of TranscendTM Technologies for more information).
2 Formic acid is mildly flammable with flashpoint of 68.9°C (156°F), lower flammability limit of 18.0% by volume, and NFPA flammability rating of 2.
3 Closed cell foam products and products containing closed cell foams (in all applications except military or space- and aeronautics-related applications) manufactured on or before January 1, 2020, may be used after that date. Closed cell foam products and products containing closed cell foams in military or space- and aeronautics-related applications manufactured or before January 1, 2025, may be used after that date.
4 Low pressure two-component spray foam kits manufactured on or before January 1, 2025, may be used after that date. [Note: EPA intends to issue a rule revision to correct this date to be consistent with the intent expressed in the preamble.]
5 One-component foam sealant cans manufactured on or before January 1, 2020, may be used after that date.