This is not the current EPA website. To navigate to the current EPA website, please go to www.epa.gov. This website is historical material reflecting the EPA website as it existed on January 19, 2021. This website is no longer updated and links to external websites and some internal pages may not work. More information »

Energy Resources for State and Local Governments

AVERT Tutorial Using AVERT Outputs in SMOKE: Overview

In addition to providing summary estimates of displaced emissions from EE/RE in Excel format, the AVERT Main Module can also produce output files for the Sparse Matrix Operator Kernel Emissions (SMOKE) modeling system.

SMOKE is primarily an emissions processing system designed to create gridded, speciated, hourly emissions for input into a variety of air quality models such as CMAQ, REMSAD, CAMX, and UAM. SMOKE supports area, biogenic, mobile (both onroad and nonroad), and point source emissions processing for criteria, particulate, and toxic pollutants.

AVERT produces 24 output files (one for each month, pre- and post-EE/RE) in ASCII format for use in SMOKE. The files are already in a format recognized by SMOKE called the Continuous Emissions Modeling (CEM) format, which has 17 columns corresponding to the table below (excerpted from the SMOKE User’s Manual).

CEM format for individual hour-specific data files:

Position Name Type Description
A ORISID Char (6) DOE Plant Identification Code (required) (should match the same field in the PTINV file in ORL format)
B BLRID Char (6) Boiler Identification Code (required) (should match the same field in the PTINV file in ORL format)
C YYMMDD Int Date of data in YYMMDD format (required)
D HOUR Integer Hour value from 0 to 23
E NOXMASS Real Nitrogen oxide emissions (lbs/hr) (required)
F SO2MASS Real Sulfur dioxide emissions (lbs/hr) (required)
G NOXRATE Real Nitrogen oxide emissions rate (lbs/MMBtu) (not used by SMOKE)
H OPTIME Real Fraction of hour unit was operating (optional)
I GLOAD Real Gross load (MW) (optional)
J SLOAD Real Steam load (1,000 lbs/hr) (optional)
K HTINPUT Real Heat input (mmBtu) (required)
L HTINPUTMEASURE Character(2) Code number indicating measured or substituted, not used by SMOKE
M SO2MEASURE Character(2) Code number indicating measured or substituted, not used by SMOKE
N NOXMMEASURE Character(2) Code number indicating measured or substituted, not used by SMOKE
O NOXRMEASURE Character(2) Code number indicating measured or substituted, not used by SMOKE
P UNITFLOW Real Flow rate (ft3/sec) for the Boiler Unit (optional; must be present for all records or not any records – not yet used by SMOKE)
Q PM25MASS Real PM2.5 emissions (lbs/hr) (optional)

 

For more information on how to download output files for SMOKE, please view the Downloading AVERT Files For Use in SMOKE Step-by-Step Instructions slides.